Frete gratis para todo o Brasil

Bus Fault Injection Board

R$ 708,00
Frete gratis para todo o Brasil
  • Compra 100% segura
  • Produtos originais com garantia
  • Emitimos NFe • Faturamos a prazo
  • Site seguro · SSL

Compre com segurança, procedência e garantia. Fornecemos para todo o Brasil, faturamos a prazo no boleto e emitimos NFe (nota fiscal eletrônica). Despachamos ou retiramos em São Paulo, SP. Produtos originais, valores unitários. Temos experiência e suporte.

Formas de pagamento
Pix VISA elo Hiper AMEX PayPal ate 12x

The board can simulate errors: a wrong termination resistor, open/shorted CAN_H or CAN_L to Gnd/Vdd, disconnected Gnd or Vdd or Shield signal. The fault injector board is suitable for CAN, CAN FD, FlexRay, RS-485, and LIN buses.

The Board has two sides - left and right. There are two D-SUB9F connectors wired 1:1 at each side. The switches for fault injection are placed between the sides. If all the switches are in "OK" position, there is no fault injected into the physical layer and left, and right sides are connected correctly. This means all four D-SUB connectors are connected 1:1 and the board can be used for a normal interconnection of network devices.


Possible to Inject Faults

  • No fault (input and output D-SUB connectors connected without any error)
  • Termination resistors (pins 2+7): the value can be changed (potentiometer 0-10 KOhm) / possibility to switch to a fixed 120 Ohm resistor
  • CAN_L (pin 2): Short to GND, Short to Vdd, Open, Partially Open (potentiometer 0-10 KOhm)
  • CAN_H (pin 7): Short to GND, Short to Vdd, Open, Partially Open (potentiometer 0-10 KOhm)
  • CAN_L shorted to CAN_H (a termination resistor of 0 Ohm)
  • Vdd open (pin 9)
  • Shield open (pin 5)
Property Value
The information herein is subject to change without notice.
Input Connectors 2x D-SUB9 F (wired 1:1)
Output Connectors 2x D-SUB9 F (wired 1:1)
Dimensions 100 x 100 mm
Terminals for connecting wires of an existing network
Test points for an oscilloscope probe at important signals
Compatible with CAN, CAN FD, FlexRay, RS-485, LIN
4x adhesive rubber pad at the bottom
Data Sheet
Bus Fault Injection Board Data Sheet

Frete grátis. Clique em SOLICITAR COTAÇÃO PROPOSTA para enviar sua cotação e receber nossa proposta em seu email. Faturamos a prazo, desconto para pagamento à vista. Impostos inclusos, parcelamos em até 12x sem juros no cartão.

Produtos originais, garantimos a compatibilidade. Somos especialistas em TI. Atendemos e fornecemos para todo o Brasil.

Emitimos NFe, nota fiscal eletrônica. Enviamos ou retira os produtos na cidade de São Paulo, SP. Compre com segurança e procedência. Produtos com garantia, temos experiência e suporte. Somos especialistas em TI.

Por favor clique em Solicitar proposta. Desta forma receberá a proposta em seu email.

Estabelecemos parcerias com revendas. Somos distribuidores e temos preços diferenciados. Fornecemos para revendas de todo o Brasil.

Oferecemos opcionalmente o faturamos direto para seu cliente com fidelização para sua empresa (vendas e atendimento exclusivo seu) e com comissionamento (pagamos comissão pela intermediação) para a revenda.

Clique em Solicitar proposta. Desta forma receberá a proposta em seu email.

Allows the user to inject faults into a physical layer of a differential network

The board can simulate errors: a wrong termination resistor, open/shorted CAN_H or CAN_L to Gnd/Vdd, disconnected Gnd or Vdd or Shield signal. The fault injector board is suitable for CAN, CAN FD, FlexRay, RS-485, and LIN buses.

The Board has two sides - left and right. There are two D-SUB9F connectors wired 1:1 at each side. The switches for fault injection are placed between the sides. If all the switches are in "OK" position, there is no fault injected into the physical layer and left, and right sides are connected correctly. This means all four D-SUB connectors are connected 1:1 and the board can be used for a normal interconnection of network devices.


Possible to Inject Faults

  • No fault (input and output D-SUB connectors connected without any error)
  • Termination resistors (pins 2+7): the value can be changed (potentiometer 0-10 KOhm) / possibility to switch to a fixed 120 Ohm resistor
  • CAN_L (pin 2): Short to GND, Short to Vdd, Open, Partially Open (potentiometer 0-10 KOhm)
  • CAN_H (pin 7): Short to GND, Short to Vdd, Open, Partially Open (potentiometer 0-10 KOhm)
  • CAN_L shorted to CAN_H (a termination resistor of 0 Ohm)
  • Vdd open (pin 9)
  • Shield open (pin 5)
Property Value
The information herein is subject to change without notice.
Input Connectors 2x D-SUB9 F (wired 1:1)
Output Connectors 2x D-SUB9 F (wired 1:1)
Dimensions 100 x 100 mm
Terminals for connecting wires of an existing network
Test points for an oscilloscope probe at important signals
Compatible with CAN, CAN FD, FlexRay, RS-485, LIN
4x adhesive rubber pad at the bottom
Data Sheet
Bus Fault Injection Board Data Sheet

Informações e formas de pagamento

Frete grátis. Clique em SOLICITAR COTAÇÃO PROPOSTA para enviar sua cotação e receber nossa proposta em seu email. Faturamos a prazo, desconto para pagamento à vista. Impostos inclusos, parcelamos em até 12x sem juros no cartão.

Produtos originais, garantimos a compatibilidade. Somos especialistas em TI. Atendemos e fornecemos para todo o Brasil.

Emitimos NFe, nota fiscal eletrônica. Enviamos ou retira os produtos na cidade de São Paulo, SP. Compre com segurança e procedência. Produtos com garantia, temos experiência e suporte. Somos especialistas em TI.

Por favor clique em Solicitar proposta. Desta forma receberá a proposta em seu email.

Estabelecemos parcerias com revendas

Estabelecemos parcerias com revendas. Somos distribuidores e temos preços diferenciados. Fornecemos para revendas de todo o Brasil.

Oferecemos opcionalmente o faturamos direto para seu cliente com fidelização para sua empresa (vendas e atendimento exclusivo seu) e com comissionamento (pagamos comissão pela intermediação) para a revenda.

Clique em Solicitar proposta. Desta forma receberá a proposta em seu email.