{"product_id":"nscomm-lc-upc-to-lc-upc-duplex-standard-clip-uniboot-single-mode-fiber-patch-cable-20mm-ofnr","title":"NSComm LC UPC to LC UPC Duplex Standard Clip Uniboot Single Mode Fiber Patch Cable, 2.0mm OFNR","description":"\u003ch3 data-start=\"96\" data-end=\"110\"\u003eOverview\u003c\/h3\u003e\n\u003cp data-start=\"112\" data-end=\"669\"\u003eThe NSComm LC UPC to LC UPC Duplex Standard Clip Uniboot Single Mode Fiber Patch Cable is a high-density OS2 interconnect solution optimized for space-constrained data center environments. Thanks to its uniboot design, both fibers are routed within a single 2.0mm jacket, significantly reducing cable bulk and improving airflow at the front of high-port-count switches and patch panels. LC UPC connectors on both ends deliver low insertion loss and high return loss, making this patch cable suitable for high-bandwidth, long-distance single mode applications.\u003c\/p\u003e\n\u003cp data-start=\"671\" data-end=\"1091\"\u003eConstructed with bend-insensitive G.657.A1 fiber and a riser-rated (OFNR) jacket, this uniboot patch cable offers low attenuation even when routed through tight spaces, making installation and maintenance more efficient. It is ideal for OS2 9\/125 μm single mode links in data centers, telecommunications networks, and enterprise environments where high-density fiber patching and clean cable management are priorities.\u003c\/p\u003e\n\u003cp data-start=\"1093\" data-end=\"1213\"\u003e\u003cem data-start=\"1093\" data-end=\"1211\"\u003eNote: Standard clip LC uniboot cables are not recommended for use with FHD 36F shuttered adapter panels \u0026amp; cassettes.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp data-start=\"1215\" data-end=\"1406\"\u003eNeed help planning high-density uniboot patching or matching this cable to your panels and transceivers? Contact us now and our team will help validate your configuration before deployment.\u003c\/p\u003e\n\u003ch4 data-start=\"1413\" data-end=\"1437\"\u003eKey Specifications\u003c\/h4\u003e\n\u003cdiv class=\"_tableContainer_80l1q_1\"\u003e\n\u003cdiv class=\"_tableWrapper_80l1q_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1439\" data-end=\"4164\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1439\" data-end=\"1563\"\u003e\n\u003ctr data-start=\"1439\" data-end=\"1563\"\u003e\n\u003cth data-start=\"1439\" data-end=\"1474\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1474\" data-end=\"1563\" data-col-size=\"md\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1688\" data-end=\"4164\"\u003e\n\u003ctr data-start=\"1688\" data-end=\"1811\"\u003e\n\u003ctd data-start=\"1688\" data-end=\"1722\" data-col-size=\"sm\"\u003eVendor Name\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1722\" data-end=\"1811\"\u003eNSComm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1812\" data-end=\"1934\"\u003e\n\u003ctd data-start=\"1812\" data-end=\"1846\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1846\" data-end=\"1934\"\u003eLC UPC to LC UPC Duplex Standard Clip Uniboot Single Mode Fiber Patch Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1935\" data-end=\"2058\"\u003e\n\u003ctd data-start=\"1935\" data-end=\"1969\" data-col-size=\"sm\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1969\" data-end=\"2058\"\u003eLC UPC to LC UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2059\" data-end=\"2182\"\u003e\n\u003ctd data-start=\"2059\" data-end=\"2093\" data-col-size=\"sm\"\u003eFiber Count\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2093\" data-end=\"2182\"\u003eDuplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2183\" data-end=\"2306\"\u003e\n\u003ctd data-start=\"2183\" data-end=\"2217\" data-col-size=\"sm\"\u003eFiber Grade\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2217\" data-end=\"2306\"\u003eG.657.A1 (Compatible with G.652.D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2307\" data-end=\"2430\"\u003e\n\u003ctd data-start=\"2307\" data-end=\"2341\" data-col-size=\"sm\"\u003eFiber Mode\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2341\" data-end=\"2430\"\u003eOS2 9\/125 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2431\" data-end=\"2554\"\u003e\n\u003ctd data-start=\"2431\" data-end=\"2465\" data-col-size=\"sm\"\u003eDurability\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2465\" data-end=\"2554\"\u003e1000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2555\" data-end=\"2678\"\u003e\n\u003ctd data-start=\"2555\" data-end=\"2589\" data-col-size=\"sm\"\u003eInsertion Loss\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2589\" data-end=\"2678\"\u003e≤ 0.20 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2679\" data-end=\"2802\"\u003e\n\u003ctd data-start=\"2679\" data-end=\"2713\" data-col-size=\"sm\"\u003eReturn Loss\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2713\" data-end=\"2802\"\u003e≥ 50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2803\" data-end=\"2926\"\u003e\n\u003ctd data-start=\"2803\" data-end=\"2837\" data-col-size=\"sm\"\u003eAttenuation @ 1310 nm\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2837\" data-end=\"2926\"\u003e0.4 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2927\" data-end=\"3050\"\u003e\n\u003ctd data-start=\"2927\" data-end=\"2961\" data-col-size=\"sm\"\u003eAttenuation @ 1550 nm\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2961\" data-end=\"3050\"\u003e0.25 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3051\" data-end=\"3174\"\u003e\n\u003ctd data-start=\"3051\" data-end=\"3085\" data-col-size=\"sm\"\u003eCable Outside Diameter (OD)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3085\" data-end=\"3174\"\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3175\" data-end=\"3298\"\u003e\n\u003ctd data-start=\"3175\" data-end=\"3209\" data-col-size=\"sm\"\u003eMin. Bend Radius (Fiber Core)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3209\" data-end=\"3298\"\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3299\" data-end=\"3422\"\u003e\n\u003ctd data-start=\"3299\" data-end=\"3333\" data-col-size=\"sm\"\u003eMin. Bend Radius (Fiber Cable)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3333\" data-end=\"3422\"\u003e10\/5D (Dynamic\/Static)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3423\" data-end=\"3546\"\u003e\n\u003ctd data-start=\"3423\" data-end=\"3457\" data-col-size=\"sm\"\u003eTensile Strength\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3457\" data-end=\"3546\"\u003e60\/100 N (Long\/Short Term)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3547\" data-end=\"3670\"\u003e\n\u003ctd data-start=\"3547\" data-end=\"3581\" data-col-size=\"sm\"\u003eCable Jacket\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3581\" data-end=\"3670\"\u003eRiser (OFNR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3671\" data-end=\"3794\"\u003e\n\u003ctd data-start=\"3671\" data-end=\"3705\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3705\" data-end=\"3794\"\u003e-10 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3795\" data-end=\"3918\"\u003e\n\u003ctd data-start=\"3795\" data-end=\"3829\" data-col-size=\"sm\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3829\" data-end=\"3918\"\u003e-20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3919\" data-end=\"4041\"\u003e\n\u003ctd data-start=\"3919\" data-end=\"3953\" data-col-size=\"sm\"\u003eUsage Note\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3953\" data-end=\"4041\"\u003eNot recommended with FHD 36F shuttered adapter panels \u0026amp; cassettes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4042\" data-end=\"4164\"\u003e\n\u003ctd data-start=\"4042\" data-end=\"4076\" data-col-size=\"sm\"\u003eApplications\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4076\" data-end=\"4164\"\u003eHigh-density OS2 patching in data centers, telecom rooms, and enterprise networks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"text-align: left;\" class=\"authoritative-certification-icon\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch4 data-start=\"4171\" data-end=\"4240\"\u003eWhy Choose NSComm LC UPC to LC UPC Duplex Uniboot OS2 Patch Cables?\u003c\/h4\u003e\n\u003cul data-start=\"4242\" data-end=\"4930\"\u003e\n\u003cli data-start=\"4242\" data-end=\"4384\"\u003e\n\u003cp data-start=\"4244\" data-end=\"4384\"\u003e\u003cstrong data-start=\"4244\" data-end=\"4275\"\u003eSpace-saving uniboot design\u003c\/strong\u003e – Both fibers share a single 2.0mm jacket, reducing cable congestion and improving airflow in dense racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4385\" data-end=\"4530\"\u003e\n\u003cp data-start=\"4387\" data-end=\"4530\"\u003e\u003cstrong data-start=\"4387\" data-end=\"4418\"\u003eHigh-density patching ready\u003c\/strong\u003e – Ideal for top-of-rack and spine-leaf environments where panel space and front-of-rack clarity are critical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4531\" data-end=\"4662\"\u003e\n\u003cp data-start=\"4533\" data-end=\"4662\"\u003e\u003cstrong data-start=\"4533\" data-end=\"4568\"\u003eBend-insensitive G.657.A1 fiber\u003c\/strong\u003e – Maintains low attenuation under tight bends, simplifying routing and ongoing maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4663\" data-end=\"4796\"\u003e\n\u003cp data-start=\"4665\" data-end=\"4796\"\u003e\u003cstrong data-start=\"4665\" data-end=\"4706\"\u003eLow insertion loss \u0026amp; high return loss\u003c\/strong\u003e – LC UPC terminations provide stable, low-loss performance for long-distance OS2 links.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4797\" data-end=\"4930\"\u003e\n\u003cp data-start=\"4799\" data-end=\"4930\"\u003e\u003cstrong data-start=\"4799\" data-end=\"4832\"\u003eRiser-rated OFNR construction\u003c\/strong\u003e – Suitable for use in riser spaces, cable managers, and structured data center cabling systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"4937\" data-end=\"4957\"\u003eLength Options\u003c\/h4\u003e\n\u003cp data-start=\"4959\" data-end=\"5152\"\u003e\u003cstrong data-start=\"4959\" data-end=\"4988\"\u003eStandard stocked lengths:\u003c\/strong\u003e\u003cbr data-start=\"4988\" data-end=\"4991\"\u003eAvailable in a range of common uniboot patch cord lengths designed for switch-to-switch, switch-to-panel, and panel-to-panel connections in high-density racks.\u003c\/p\u003e\n\u003cp data-start=\"5154\" data-end=\"5336\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"5154\" data-end=\"5173\"\u003eCustom lengths:\u003c\/strong\u003e\u003cbr data-start=\"5173\" data-end=\"5176\"\u003eCustom lengths, jacket colors, labeling, and polarity options are available on request to match your specific rack layouts, cable routing, and design standards.\u003c\/p\u003e\n\u003ch3 style=\"text-align: left;\" class=\"authoritative-certification-icon\"\u003eMore Details\u003c\/h3\u003e\n\u003ch4 class=\"authoritative-certification-icon\" style=\"text-align: left;\"\u003eQuality Certifications\u003cb\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/3Y_Warranty_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO9001-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO14001-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO27001-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/ISO45001-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/CE-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/Reach-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/CB-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/cURus-UL_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/FCC-SFP_50x50.png?v=1753520941\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0736\/7566\/9719\/files\/UKCA-SFP_50x50.png?v=1753521101\" style=\"margin-bottom: 16px; float: none;\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003eDo you have any question about the NSComm LC to LC UPC Duplex Uniboot Fiber Patch Cable?\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: left;\" class=\"authoritative-certification-icon\"\u003ePlease \u003ca href=\"#chatty-chat\"\u003eChat with us\u003c\/a\u003e now!\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" class=\"authoritative-certification-icon\"\u003eor leave us an message on \u003ca href=\"mailto:sales@network-switch.com\"\u003esales@network-switch.com\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4 class=\"pb-4 mb-4\"\u003eWarranty\u003c\/h4\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6 pr-md-5\"\u003e\n\u003ci class=\"i1\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003e100% Low Price Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNetwork-switch.com provides high-quality products at low wholesale prices\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6\"\u003e\n\u003ci class=\"i2\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003e100% Quality Assurance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll items are ORIGINAL and GENUINE only.\u003cbr\u003eItem conditions are \"New Sealed\". They are fully tested by Certified CCIE \/ HCIE \/ RCNP Engineers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6 pr-md-5\"\u003e\n\u003ci class=\"i4\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003eFree Technical Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOur FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_2 col-12 col-md-6\"\u003e\n\u003ci class=\"i3\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003e100% Money Back Guarantee\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can contact our customer service team to exchange or return any product that you bought from us.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"detaildl_3 col-12 col-md-6 pr-md-5\"\u003e\n\u003ci class=\"i\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003eStandard Warranty Policy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOriginal New Sealed Enterprise Hardware: 3 Years\u003cbr\u003eOriginal New Sealed Consumer Devices: 1 Year\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detaildl_3 col-12 col-md-6\"\u003e\n\u003ci class=\"i\"\u003e\u003c\/i\u003e\n\u003cdiv class=\"\"\u003e\n\u003cp class=\"font16 color333 mb-2\"\u003e\u003cstrong\u003eThe Support Contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf your NSComm products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Network-Switch \u0026 NS","offers":[{"title":"1m (3ft)","offer_id":46598123126945,"sku":"NS-LCLCUU2FSM-UN-1","price":1092.0,"currency_code":"BRL","in_stock":true},{"title":"2m (7ft)","offer_id":46598123159713,"sku":"NS-LCLCUU2FSM-UN-2","price":1584.0,"currency_code":"BRL","in_stock":true},{"title":"3m (10ft)","offer_id":46598123192481,"sku":"NS-LCLCUU2FSM-UN-3","price":1788.0,"currency_code":"BRL","in_stock":true},{"title":"5m (16ft)","offer_id":46598123225249,"sku":"NS-LCLCUU2FSM-UN-4","price":2184.0,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2216\/8673\/files\/LC-LC-UPC-duplex-uniboot-OS2.jpg?v=1782317567","url":"https:\/\/www.foxti.com.br\/products\/nscomm-lc-upc-to-lc-upc-duplex-standard-clip-uniboot-single-mode-fiber-patch-cable-20mm-ofnr","provider":"FoxTI","version":"1.0","type":"link"}