{"product_id":"intel-1536tb-nvme-u2-pcie-gen-30-x4-ri-sff-25-ssd-d5-p4326-series-ssdpe2nv153t8","title":"Intel 15.36TB NVMe U.2 PCIe Gen 3.0 x4 RI SFF 2.5\" SSD D5-P4326 Series SSDPE2NV153T8","description":"\u003csection data-scroll-anchor=\"true\" data-testid=\"conversation-turn-146\" data-turn=\"assistant\" data-turn-id=\"request-69c2f210-e80c-832f-a3b7-05e7762044c7-21\" dir=\"auto\"\u003e\n\u003cp data-end=\"85\" data-start=\"0\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"85\" data-start=\"0\"\u003eIntel 15.36TB NVMe U.2 PCIe Gen3 x4 RI SFF 2.5\" SSD D5-P4326 Series SSDPE2NV153T8\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp data-end=\"467\" data-start=\"87\" style=\"text-align: justify;\"\u003eThe \u003cstrong data-end=\"171\" data-start=\"91\"\u003eIntel D5-P4326 Series (Model: SSDPE2NV153T8)\u003c\/strong\u003e is a high-capacity, enterprise NVMe SSD engineered for read-intensive (RI) workloads. Built with 64-layer QLC 3D NAND, it delivers exceptional storage density in a standard 2.5\" U.2 form factor—ideal for data lakes, content delivery, and replacing traditional HDD storage in modern data centers.\u003c\/p\u003e\n\n\u003chr data-end=\"472\" data-start=\"469\"\u003e\n\u003ch3 data-end=\"502\" data-section-id=\"5cy232\" data-start=\"474\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"502\" data-start=\"478\"\u003eRelated Part Numbers\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"624\" data-start=\"503\" style=\"text-align: justify;\"\u003eSSDPE2NV153T8, SSDPE2NV153T801, J67810-075, 73-0004-01\u003c\/p\u003e\n\n\u003chr data-end=\"629\" data-start=\"626\"\u003e\n\u003ch3 data-end=\"668\" data-section-id=\"1niyif4\" data-start=\"631\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"668\" data-start=\"635\"\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"862\" data-start=\"669\"\u003e\n\t\u003cli data-end=\"694\" data-section-id=\"1cxgu2n\" data-start=\"669\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"684\" data-start=\"671\"\u003eCapacity:\u003c\/strong\u003e 15.36TB\u003c\/li\u003e\n\t\u003cli data-end=\"725\" data-section-id=\"1415ews\" data-start=\"695\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"708\" data-start=\"697\"\u003eSeries:\u003c\/strong\u003e Intel D5-P4326\u003c\/li\u003e\n\t\u003cli data-end=\"768\" data-section-id=\"10hxael\" data-start=\"726\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"742\" data-start=\"728\"\u003eInterface:\u003c\/strong\u003e PCIe Gen3 x4 (NVMe 1.x)\u003c\/li\u003e\n\t\u003cli data-end=\"822\" data-section-id=\"18toh47\" data-start=\"769\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"787\" data-start=\"771\"\u003eForm Factor:\u003c\/strong\u003e 2.5\" U.2 (SFF-8639), 15mm height\u003c\/li\u003e\n\t\u003cli data-end=\"862\" data-section-id=\"1rscrsf\" data-start=\"823\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"839\" data-start=\"825\"\u003eNAND Type:\u003c\/strong\u003e 64-layer QLC 3D NAND\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"867\" data-start=\"864\"\u003e\n\u003ch3 data-end=\"888\" data-section-id=\"1lfaz9a\" data-start=\"869\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"888\" data-start=\"873\"\u003ePerformance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1118\" data-start=\"889\"\u003e\n\t\u003cli data-end=\"930\" data-section-id=\"1799ekp\" data-start=\"889\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"911\" data-start=\"891\"\u003eSequential Read:\u003c\/strong\u003e Up to 3,200 MB\/s\u003c\/li\u003e\n\t\u003cli data-end=\"973\" data-section-id=\"1n1n140\" data-start=\"931\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"954\" data-start=\"933\"\u003eSequential Write:\u003c\/strong\u003e Up to 1,600 MB\/s\u003c\/li\u003e\n\t\u003cli data-end=\"1018\" data-section-id=\"jtqfbz\" data-start=\"974\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"997\" data-start=\"976\"\u003eRandom Read (4K):\u003c\/strong\u003e Up to 580,000 IOPS\u003c\/li\u003e\n\t\u003cli data-end=\"1058\" data-section-id=\"ddmj4n\" data-start=\"1019\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1038\" data-start=\"1021\"\u003eRandom Write:\u003c\/strong\u003e Up to 15,000 IOPS\u003c\/li\u003e\n\t\u003cli data-end=\"1088\" data-section-id=\"1i3t2uf\" data-start=\"1059\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1078\" data-start=\"1061\"\u003eRead Latency:\u003c\/strong\u003e ~135 µs\u003c\/li\u003e\n\t\u003cli data-end=\"1118\" data-section-id=\"15rv8pl\" data-start=\"1089\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1109\" data-start=\"1091\"\u003eWrite Latency:\u003c\/strong\u003e ~60 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1123\" data-start=\"1120\"\u003e\n\u003ch3 data-end=\"1156\" data-section-id=\"zqh55d\" data-start=\"1125\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1156\" data-start=\"1129\"\u003eEndurance \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1452\" data-start=\"1157\"\u003e\n\t\u003cli data-end=\"1199\" data-section-id=\"12otf6c\" data-start=\"1157\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1177\" data-start=\"1159\"\u003eWorkload Type:\u003c\/strong\u003e Read Intensive (RI)\u003c\/li\u003e\n\t\u003cli data-end=\"1275\" data-section-id=\"18lbpzo\" data-start=\"1200\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1216\" data-start=\"1202\"\u003eEndurance:\u003c\/strong\u003e\n\t\u003cul data-end=\"1275\" data-start=\"1221\"\u003e\n\t\t\u003cli data-end=\"1253\" data-section-id=\"16tbiu3\" data-start=\"1221\"\u003eUp to ~24.6 PBW (Sequential)\u003c\/li\u003e\n\t\t\u003cli data-end=\"1275\" data-section-id=\"1baqy58\" data-start=\"1256\"\u003e~5 PBW (Random)\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1330\" data-section-id=\"1n6exeu\" data-start=\"1276\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1287\" data-start=\"1278\"\u003eDWPD:\u003c\/strong\u003e ~0.18 (random) \/ up to ~0.9 (sequential)\u003c\/li\u003e\n\t\u003cli data-end=\"1360\" data-section-id=\"dudf1e\" data-start=\"1331\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1342\" data-start=\"1333\"\u003eMTBF:\u003c\/strong\u003e 2 million hours\u003c\/li\u003e\n\t\u003cli data-end=\"1452\" data-section-id=\"1avm7p7\" data-start=\"1361\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1383\" data-start=\"1363\"\u003eData Protection:\u003c\/strong\u003e\n\t\u003cul data-end=\"1452\" data-start=\"1388\"\u003e\n\t\t\u003cli data-end=\"1419\" data-section-id=\"1vvo67u\" data-start=\"1388\"\u003ePower Loss Protection (PLP)\u003c\/li\u003e\n\t\t\u003cli data-end=\"1452\" data-section-id=\"1qonhds\" data-start=\"1422\"\u003eEnd-to-End Data Protection\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1457\" data-start=\"1454\"\u003e\n\u003ch3 data-end=\"1488\" data-section-id=\"qquco7\" data-start=\"1459\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1488\" data-start=\"1463\"\u003ePower \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1659\" data-start=\"1489\"\u003e\n\t\u003cli data-end=\"1515\" data-section-id=\"1km2ctm\" data-start=\"1489\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1508\" data-start=\"1491\"\u003eActive Power:\u003c\/strong\u003e ~20W\u003c\/li\u003e\n\t\u003cli data-end=\"1539\" data-section-id=\"qaya1h\" data-start=\"1516\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1533\" data-start=\"1518\"\u003eIdle Power:\u003c\/strong\u003e ~5W\u003c\/li\u003e\n\t\u003cli data-end=\"1582\" data-section-id=\"10q3ptb\" data-start=\"1540\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1568\" data-start=\"1542\"\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 70°C\u003c\/li\u003e\n\t\u003cli data-end=\"1659\" data-section-id=\"df6klp\" data-start=\"1583\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1605\" data-start=\"1585\"\u003eShock\/Vibration:\u003c\/strong\u003e Enterprise-grade durability (1000G shock tolerance)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1664\" data-start=\"1661\"\u003e\n\u003ch3 data-end=\"1686\" data-section-id=\"pm8yra\" data-start=\"1666\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1686\" data-start=\"1670\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2135\" data-start=\"1687\"\u003e\n\t\u003cli data-end=\"1787\" data-section-id=\"1p6ha9n\" data-start=\"1687\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1720\" data-start=\"1689\"\u003eMassive Density (QLC NAND):\u003c\/strong\u003e\u003cbr data-end=\"1723\" data-start=\"1720\"\u003e\n\tOptimized for high-capacity deployments with low cost per TB\u003c\/li\u003e\n\t\u003cli data-end=\"1904\" data-section-id=\"1hkhnli\" data-start=\"1789\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1822\" data-start=\"1791\"\u003eRead-Optimized Performance:\u003c\/strong\u003e\u003cbr data-end=\"1825\" data-start=\"1822\"\u003e\n\tHigh sequential read throughput ideal for streaming and analytics workloads\u003c\/li\u003e\n\t\u003cli data-end=\"2020\" data-section-id=\"vvlcmd\" data-start=\"1906\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1939\" data-start=\"1908\"\u003eEnterprise Data Protection:\u003c\/strong\u003e\u003cbr data-end=\"1942\" data-start=\"1939\"\u003e\n\tIntegrated safeguards ensure data integrity during unexpected power events\u003c\/li\u003e\n\t\u003cli data-end=\"2135\" data-section-id=\"z221a0\" data-start=\"2022\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2053\" data-start=\"2024\"\u003eHDD Replacement Use Case:\u003c\/strong\u003e\u003cbr data-end=\"2056\" data-start=\"2053\"\u003e\n\tPerfect for transitioning from spinning disks to all-flash or hybrid arrays\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2140\" data-start=\"2137\"\u003e\n\u003ch3 data-end=\"2167\" data-section-id=\"1hu8n6g\" data-start=\"2142\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2167\" data-start=\"2146\"\u003eTypical Use Cases\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2363\" data-start=\"2168\"\u003e\n\t\u003cli data-end=\"2203\" data-section-id=\"wq3o9k\" data-start=\"2168\" style=\"text-align: justify;\"\u003eContent Delivery Networks (CDN)\u003c\/li\u003e\n\t\u003cli data-end=\"2239\" data-section-id=\"pf2zn2\" data-start=\"2204\" style=\"text-align: justify;\"\u003eData lakes \/ warm storage tiers\u003c\/li\u003e\n\t\u003cli data-end=\"2278\" data-section-id=\"cc5hwf\" data-start=\"2240\" style=\"text-align: justify;\"\u003eRead-heavy databases and analytics\u003c\/li\u003e\n\t\u003cli data-end=\"2322\" data-section-id=\"c007mh\" data-start=\"2279\" style=\"text-align: justify;\"\u003eObject storage and cloud infrastructure\u003c\/li\u003e\n\t\u003cli data-end=\"2363\" data-section-id=\"2kwm21\" data-start=\"2323\" style=\"text-align: justify;\"\u003eHigh-capacity virtualization storage\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2368\" data-start=\"2365\"\u003e\n\u003ch3 data-end=\"2391\" data-section-id=\"n07754\" data-start=\"2370\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2391\" data-start=\"2374\"\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ch4 data-end=\"2420\" data-start=\"2393\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2420\" data-start=\"2398\"\u003eEnterprise Servers\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cp data-end=\"2477\" data-start=\"2421\" style=\"text-align: justify;\"\u003eCompatible with systems that support NVMe U.2 (PCIe x4):\u003c\/p\u003e\n\n\u003cul data-end=\"2750\" data-start=\"2478\"\u003e\n\t\u003cli data-end=\"2551\" data-section-id=\"164lwki\" data-start=\"2478\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2499\" data-start=\"2480\"\u003eDell PowerEdge:\u003c\/strong\u003e R640, R740, R740xd, R750, C6400 (NVMe-configured)\u003c\/li\u003e\n\t\u003cli data-end=\"2628\" data-section-id=\"ahcody\" data-start=\"2552\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2571\" data-start=\"2554\"\u003eHPE ProLiant:\u003c\/strong\u003e DL360, DL380 (Gen10 \/ Gen10 Plus with NVMe backplanes)\u003c\/li\u003e\n\t\u003cli data-end=\"2691\" data-section-id=\"1uqwgwn\" data-start=\"2629\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2654\" data-start=\"2631\"\u003eLenovo ThinkSystem:\u003c\/strong\u003e SR630, SR650 (AnyBay\/NVMe configs)\u003c\/li\u003e\n\t\u003cli data-end=\"2750\" data-section-id=\"sphgyh\" data-start=\"2692\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2709\" data-start=\"2694\"\u003eSupermicro:\u003c\/strong\u003e Ultra, WIO, and NVMe-enabled platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4 data-end=\"2782\" data-start=\"2752\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2782\" data-start=\"2757\"\u003eHardware Requirements\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul data-end=\"3007\" data-start=\"2783\"\u003e\n\t\u003cli data-end=\"2844\" data-section-id=\"1ws9mub\" data-start=\"2783\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2799\" data-start=\"2785\"\u003eInterface:\u003c\/strong\u003e PCIe Gen3 x4 (backward\/forward compatible)\u003c\/li\u003e\n\t\u003cli data-end=\"2878\" data-section-id=\"i87m77\" data-start=\"2845\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2861\" data-start=\"2847\"\u003eConnector:\u003c\/strong\u003e U.2 (SFF-8639)\u003c\/li\u003e\n\t\u003cli data-end=\"2948\" data-section-id=\"d3edg4\" data-start=\"2879\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2895\" data-start=\"2881\"\u003eBackplane:\u003c\/strong\u003e Must be NVMe-enabled (SAS\/SATA-only will NOT work)\u003c\/li\u003e\n\t\u003cli data-end=\"3007\" data-section-id=\"1h840eg\" data-start=\"2949\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2963\" data-start=\"2951\"\u003eCabling:\u003c\/strong\u003e OCuLink, SlimSAS, or Mini-SAS HD for NVMe\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4 data-end=\"3036\" data-start=\"3009\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"3036\" data-start=\"3014\"\u003eController Support\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul data-end=\"3186\" data-start=\"3037\"\u003e\n\t\u003cli data-end=\"3070\" data-section-id=\"13yqpde\" data-start=\"3037\" style=\"text-align: justify;\"\u003eIntel VROC (NVMe RAID on CPU)\u003c\/li\u003e\n\t\u003cli data-end=\"3134\" data-section-id=\"1imlzee\" data-start=\"3071\" style=\"text-align: justify;\"\u003eBroadcom\/MegaRAID Tri-Mode controllers (94xx \/ 95xx series)\u003c\/li\u003e\n\t\u003cli data-end=\"3186\" data-section-id=\"5b8bzn\" data-start=\"3135\" style=\"text-align: justify;\"\u003eMicrochip SmartRAID NVMe-compatible controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"3191\" data-start=\"3188\"\u003e\n\u003ch3 data-end=\"3223\" data-section-id=\"lib8rr\" data-start=\"3193\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"3223\" data-start=\"3197\"\u003eSoftware Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"3414\" data-start=\"3224\"\u003e\n\t\u003cli data-end=\"3285\" data-section-id=\"1ylvog7\" data-start=\"3224\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"3238\" data-start=\"3226\"\u003eWindows:\u003c\/strong\u003e Windows 10\/11, Windows Server 2016\/2019\/2022\u003c\/li\u003e\n\t\u003cli data-end=\"3342\" data-section-id=\"193z6jm\" data-start=\"3286\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"3298\" data-start=\"3288\"\u003eLinux:\u003c\/strong\u003e RHEL, Ubuntu, SLES, CentOS (Kernel 3.10+)\u003c\/li\u003e\n\t\u003cli data-end=\"3414\" data-section-id=\"18mdzc8\" data-start=\"3343\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"3364\" data-start=\"3345\"\u003eVirtualization:\u003c\/strong\u003e VMware ESXi 6.7+ (including vSAN capacity tier)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"3419\" data-start=\"3416\"\u003e\n\u003ch3 data-end=\"3454\" data-section-id=\"prd277\" data-start=\"3421\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"3454\" data-start=\"3425\"\u003eWorkstation \/ Desktop Use\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"3627\" data-start=\"3455\"\u003e\n\t\u003cli data-end=\"3555\" data-section-id=\"xkmd5s\" data-start=\"3455\" style=\"text-align: justify;\"\u003eCan be used with:\n\t\u003cul data-end=\"3555\" data-start=\"3477\"\u003e\n\t\t\u003cli data-end=\"3505\" data-section-id=\"olmndo\" data-start=\"3477\"\u003eU.2 → PCIe adapter cards\u003c\/li\u003e\n\t\t\u003cli data-end=\"3555\" data-section-id=\"1d5i6gw\" data-start=\"3508\"\u003eU.2 → M.2 adapters (if NVMe boot supported)\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"3627\" data-section-id=\"1fs57ie\" data-start=\"3556\" style=\"text-align: justify;\"\u003eCompatible with high-end workstations (Dell Precision, HP Z-series)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"3632\" data-start=\"3629\"\u003e\n\u003ch3 data-end=\"3657\" data-section-id=\"1ws83tv\" data-start=\"3634\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"3657\" data-start=\"3638\"\u003eImportant Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"3933\" data-start=\"3658\"\u003e\n\t\u003cli data-end=\"3740\" data-section-id=\"t93ijo\" data-start=\"3658\" style=\"text-align: justify;\"\u003eThis is a \u003cstrong data-end=\"3693\" data-start=\"3670\"\u003eRead-Intensive (RI)\u003c\/strong\u003e SSD — not suitable for heavy write workloads\u003c\/li\u003e\n\t\u003cli data-end=\"3809\" data-section-id=\"e6ho05\" data-start=\"3741\" style=\"text-align: justify;\"\u003eRequires an \u003cstrong data-end=\"3807\" data-start=\"3755\"\u003eNVMe-enabled backplane or direct PCIe connection\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli data-end=\"3933\" data-section-id=\"8lv1va\" data-start=\"3810\" style=\"text-align: justify;\"\u003eQLC NAND prioritizes capacity over endurance—choose Mixed-Use (MU) drives (like D7 series) for write-heavy environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"3938\" data-start=\"3935\"\u003e\n\u003ch3 data-end=\"3955\" data-section-id=\"3l32ru\" data-start=\"3940\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"3955\" data-start=\"3944\"\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"4328\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"3956\" style=\"text-align: justify;\"\u003eThe Intel D5-P4326 15.36TB (SSDPE2NV153T8) is a purpose-built enterprise NVMe SSD for high-capacity, read-dominant workloads. With its QLC NAND architecture, strong sequential read performance, and robust enterprise reliability features, it is an excellent solution for scaling storage efficiently while reducing total cost per terabyte in modern data center environments.\u003c\/p\u003e\n\u003c\/section\u003e\n","brand":"Intel","offers":[{"title":"Default Title","offer_id":46466195423393,"sku":"SSDPE2NV153T8","price":56999.85,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2216\/8673\/files\/Intel-15_36TB-NVMe-U_2-PCIe-Gen-3_0-x4-RI-SFF-2_5-SSD-D5-P4326-Series-SSDPE2NV153T8.png?v=1779963640","url":"https:\/\/www.foxti.com.br\/products\/intel-1536tb-nvme-u2-pcie-gen-30-x4-ri-sff-25-ssd-d5-p4326-series-ssdpe2nv153t8","provider":"FoxTI","version":"1.0","type":"link"}