{"product_id":"hpe-h240-12g-2-port-sassata-smart-host-bus-adapter-hba-726907-b21-779134-001","title":"HPE H240 12G 2 Port SAS\/SATA Smart Host Bus Adapter (HBA) 726907-B21 779134-001","description":"\u003ch2 data-end=\"329\" data-start=\"251\" style=\"text-align: justify;\"\u003eHPE H240 12G 2-Port Internal SAS \/ SATA PCIe Smart Host Bus Adapter (HBA)\u003c\/h2\u003e\n\n\u003cp data-end=\"423\" data-start=\"330\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"373\" data-start=\"330\"\u003eOption \/ Spare \/ Assembly Part Numbers:\u003c\/strong\u003e 726907-B21 · 726909-001 · 750053-001 · 779134-001\u003c\/p\u003e\n\n\u003cp data-end=\"807\" data-start=\"425\" style=\"text-align: justify;\"\u003eThe \u003cstrong data-end=\"470\" data-start=\"429\"\u003eHPE H240 Smart Host Bus Adapter (HBA)\u003c\/strong\u003e is a \u003cstrong data-end=\"531\" data-start=\"476\"\u003e12Gb\/s internal SAS \/ 6Gb\/s SATA storage controller\u003c\/strong\u003e designed for \u003cstrong data-end=\"574\" data-start=\"545\"\u003eHPE ProLiant Gen9 servers\u003c\/strong\u003e. All listed part numbers — \u003cstrong data-end=\"656\" data-start=\"602\"\u003e726907-B21, 726909-001, 750053-001, and 779134-001\u003c\/strong\u003e — refer to the \u003cstrong data-end=\"702\" data-start=\"672\"\u003esame base HPE H240 product\u003c\/strong\u003e, with differences only reflecting \u003cstrong data-end=\"767\" data-start=\"737\"\u003eHPE lifecycle designations\u003c\/strong\u003e such as option kit, spare, or assembly.\u003c\/p\u003e\n\n\u003ch3 data-end=\"849\" data-start=\"809\" style=\"text-align: justify;\"\u003ePart Number Relationship (Important)\u003c\/h3\u003e\n\n\u003cul data-end=\"992\" data-start=\"850\"\u003e\n\t\u003cli data-end=\"885\" data-start=\"850\"\u003e\n\t\u003cp data-end=\"885\" data-start=\"852\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"866\" data-start=\"852\"\u003e726907-B21\u003c\/strong\u003e – HPE Option Kit\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"921\" data-start=\"886\"\u003e\n\t\u003cp data-end=\"921\" data-start=\"888\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"902\" data-start=\"888\"\u003e726909-001\u003c\/strong\u003e – HPE Spare Part\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"992\" data-start=\"922\"\u003e\n\t\u003cp data-end=\"992\" data-start=\"924\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"951\" data-start=\"924\"\u003e750053-001 \/ 779134-001\u003c\/strong\u003e – HPE Assembly \/ Manufacturing Numbers\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cblockquote data-end=\"1084\" data-start=\"993\"\u003e\n\u003cp data-end=\"1084\" data-start=\"995\" style=\"text-align: justify;\"\u003e\u003cem data-end=\"1084\" data-start=\"995\"\u003eFunctionality, specifications, and compatibility are identical across all part numbers.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\n\u003ch3 data-end=\"1103\" data-start=\"1086\" style=\"text-align: justify;\"\u003eCompatibility\u003c\/h3\u003e\n\n\u003cul data-end=\"1196\" data-start=\"1104\"\u003e\n\t\u003cli data-end=\"1196\" data-start=\"1104\"\u003e\n\t\u003cp data-end=\"1148\" data-start=\"1106\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1128\" data-start=\"1106\"\u003eSupported Servers:\u003c\/strong\u003e HPE ProLiant Gen9\u003c\/p\u003e\n\n\t\u003cul data-end=\"1196\" data-start=\"1151\"\u003e\n\t\t\u003cli data-end=\"1164\" data-start=\"1151\"\u003e\n\t\t\u003cp data-end=\"1164\" data-start=\"1153\" style=\"text-align: justify;\"\u003eDL Series\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"1180\" data-start=\"1167\"\u003e\n\t\t\u003cp data-end=\"1180\" data-start=\"1169\" style=\"text-align: justify;\"\u003eML Series\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"1196\" data-start=\"1183\"\u003e\n\t\t\u003cp data-end=\"1196\" data-start=\"1185\" style=\"text-align: justify;\"\u003eXL Series\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"1229\" data-start=\"1198\" style=\"text-align: justify;\"\u003eController \u0026amp; Host Interface\u003c\/h3\u003e\n\n\u003cul data-end=\"1441\" data-start=\"1230\"\u003e\n\t\u003cli data-end=\"1304\" data-start=\"1230\"\u003e\n\t\u003cp data-end=\"1304\" data-start=\"1232\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1248\" data-start=\"1232\"\u003eDevice Type:\u003c\/strong\u003e Smart Host Bus Adapter (HBA) \/ Simple RAID Controller\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1342\" data-start=\"1305\"\u003e\n\t\u003cp data-end=\"1342\" data-start=\"1307\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1320\" data-start=\"1307\"\u003eHost Bus:\u003c\/strong\u003e PCI Express Gen3 x8\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1441\" data-start=\"1343\"\u003e\n\t\u003cp data-end=\"1441\" data-start=\"1345\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1361\" data-start=\"1345\"\u003eForm Factor:\u003c\/strong\u003e Plug-in card, low profile\u003cbr data-end=\"1390\" data-start=\"1387\"\u003e\n\t\u003cem data-end=\"1439\" data-start=\"1392\"\u003e(Full-height bracket included with some SKUs)\u003c\/em\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"1465\" data-start=\"1443\" style=\"text-align: justify;\"\u003eStorage Interfaces\u003c\/h3\u003e\n\n\u003cul data-end=\"1620\" data-start=\"1466\"\u003e\n\t\u003cli data-end=\"1526\" data-start=\"1466\"\u003e\n\t\u003cp data-end=\"1492\" data-start=\"1468\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1490\" data-start=\"1468\"\u003eInterface Support:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul data-end=\"1526\" data-start=\"1495\"\u003e\n\t\t\u003cli data-end=\"1509\" data-start=\"1495\"\u003e\n\t\t\u003cp data-end=\"1509\" data-start=\"1497\" style=\"text-align: justify;\"\u003eSAS 12Gb\/s\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"1526\" data-start=\"1512\"\u003e\n\t\t\u003cp data-end=\"1526\" data-start=\"1514\" style=\"text-align: justify;\"\u003eSATA 6Gb\/s\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1574\" data-start=\"1527\"\u003e\n\t\u003cp data-end=\"1574\" data-start=\"1529\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1539\" data-start=\"1529\"\u003ePorts:\u003c\/strong\u003e 2 × internal Mini-SAS (SFF-8087)\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1620\" data-start=\"1575\"\u003e\n\t\u003cp data-end=\"1620\" data-start=\"1577\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1590\" data-start=\"1577\"\u003eChannels:\u003c\/strong\u003e 8 physical links (4 per port)\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"1648\" data-start=\"1622\" style=\"text-align: justify;\"\u003ePerformance \u0026amp; Capacity\u003c\/h3\u003e\n\n\u003cul data-end=\"1868\" data-start=\"1649\"\u003e\n\t\u003cli data-end=\"1738\" data-start=\"1649\"\u003e\n\t\u003cp data-end=\"1676\" data-start=\"1651\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1674\" data-start=\"1651\"\u003eData Transfer Rate:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul data-end=\"1738\" data-start=\"1679\"\u003e\n\t\t\u003cli data-end=\"1708\" data-start=\"1679\"\u003e\n\t\t\u003cp data-end=\"1708\" data-start=\"1681\" style=\"text-align: justify;\"\u003eUp to 12Gb\/s per SAS lane\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"1738\" data-start=\"1711\"\u003e\n\t\t\u003cp data-end=\"1738\" data-start=\"1713\" style=\"text-align: justify;\"\u003eUp to 1.2 GB\/s per port\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1868\" data-start=\"1739\"\u003e\n\t\u003cp data-end=\"1773\" data-start=\"1741\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1771\" data-start=\"1741\"\u003eMaximum Devices Supported:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul data-end=\"1868\" data-start=\"1776\"\u003e\n\t\t\u003cli data-end=\"1821\" data-start=\"1776\"\u003e\n\t\t\u003cp data-end=\"1821\" data-start=\"1778\" style=\"text-align: justify;\"\u003eUp to \u003cstrong data-end=\"1807\" data-start=\"1784\"\u003e200 physical drives\u003c\/strong\u003e in HBA mode\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"1868\" data-start=\"1824\"\u003e\n\t\t\u003cp data-end=\"1868\" data-start=\"1826\" style=\"text-align: justify;\"\u003eUp to \u003cstrong data-end=\"1853\" data-start=\"1832\"\u003e64 logical drives\u003c\/strong\u003e in RAID mode\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"1896\" data-start=\"1870\" style=\"text-align: justify;\"\u003eRAID \u0026amp; Operating Modes\u003c\/h3\u003e\n\n\u003cul data-end=\"2132\" data-start=\"1897\"\u003e\n\t\u003cli data-end=\"1975\" data-start=\"1897\"\u003e\n\t\u003cp data-end=\"1922\" data-start=\"1899\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1920\" data-start=\"1899\"\u003eSelectable Modes:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul data-end=\"1975\" data-start=\"1925\"\u003e\n\t\t\u003cli data-end=\"1952\" data-start=\"1925\"\u003e\n\t\t\u003cp data-end=\"1952\" data-start=\"1927\" style=\"text-align: justify;\"\u003eHBA (pass-through) mode\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"1975\" data-start=\"1955\"\u003e\n\t\t\u003cp data-end=\"1975\" data-start=\"1957\" style=\"text-align: justify;\"\u003eSimple RAID mode\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2045\" data-start=\"1976\"\u003e\n\t\u003cp data-end=\"2006\" data-start=\"1978\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2004\" data-start=\"1978\"\u003eSupported RAID Levels:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul data-end=\"2045\" data-start=\"2009\"\u003e\n\t\t\u003cli data-end=\"2019\" data-start=\"2009\"\u003e\n\t\t\u003cp data-end=\"2019\" data-start=\"2011\" style=\"text-align: justify;\"\u003eRAID 0\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"2032\" data-start=\"2022\"\u003e\n\t\t\u003cp data-end=\"2032\" data-start=\"2024\" style=\"text-align: justify;\"\u003eRAID 1\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"2045\" data-start=\"2035\"\u003e\n\t\t\u003cp data-end=\"2045\" data-start=\"2037\" style=\"text-align: justify;\"\u003eRAID 5\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2132\" data-start=\"2046\"\u003e\n\t\u003cp data-end=\"2075\" data-start=\"2048\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2073\" data-start=\"2048\"\u003eCache \/ Acceleration:\u003c\/strong\u003e\u003c\/p\u003e\n\n\t\u003cul data-end=\"2132\" data-start=\"2078\"\u003e\n\t\t\u003cli data-end=\"2098\" data-start=\"2078\"\u003e\n\t\t\u003cp data-end=\"2098\" data-start=\"2080\" style=\"text-align: justify;\"\u003eNo cache support\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"2132\" data-start=\"2101\"\u003e\n\t\t\u003cp data-end=\"2132\" data-start=\"2103\" style=\"text-align: justify;\"\u003eNo flash-backed write cache\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"2155\" data-start=\"2134\" style=\"text-align: justify;\"\u003eSupported Devices\u003c\/h3\u003e\n\n\u003cul data-end=\"2222\" data-start=\"2156\"\u003e\n\t\u003cli data-end=\"2168\" data-start=\"2156\"\u003e\n\t\u003cp data-end=\"2168\" data-start=\"2158\" style=\"text-align: justify;\"\u003eSAS HDDs\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2182\" data-start=\"2169\"\u003e\n\t\u003cp data-end=\"2182\" data-start=\"2171\" style=\"text-align: justify;\"\u003eSATA HDDs\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2202\" data-start=\"2183\"\u003e\n\t\u003cp data-end=\"2202\" data-start=\"2185\" style=\"text-align: justify;\"\u003eSAS \u0026amp; SATA SSDs\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2222\" data-start=\"2203\"\u003e\n\t\u003cp data-end=\"2222\" data-start=\"2205\" style=\"text-align: justify;\"\u003eSAS tape drives\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"2251\" data-start=\"2224\" style=\"text-align: justify;\"\u003ePhysical Specifications\u003c\/h3\u003e\n\n\u003cul data-end=\"2319\" data-start=\"2252\"\u003e\n\t\u003cli data-end=\"2319\" data-start=\"2252\"\u003e\n\t\u003cp data-end=\"2319\" data-start=\"2254\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2269\" data-start=\"2254\"\u003eDimensions:\u003c\/strong\u003e 6.6 × 2.7 × 0.6 in\u003cbr data-end=\"2291\" data-start=\"2288\"\u003e\n\t\u003cem data-end=\"2317\" data-start=\"2293\"\u003e(16.8 × 6.86 × 1.6 cm)\u003c\/em\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"2344\" data-start=\"2321\" style=\"text-align: justify;\"\u003eAdditional Features\u003c\/h3\u003e\n\n\u003cul data-end=\"2524\" data-start=\"2345\"\u003e\n\t\u003cli data-end=\"2425\" data-start=\"2345\"\u003e\n\t\u003cp data-end=\"2425\" data-start=\"2347\" style=\"text-align: justify;\"\u003eDesigned for \u003cstrong data-end=\"2394\" data-start=\"2360\"\u003esoftware-defined storage (SDS)\u003c\/strong\u003e and pass-through deployments\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2469\" data-start=\"2426\"\u003e\n\t\u003cp data-end=\"2469\" data-start=\"2428\" style=\"text-align: justify;\"\u003eLower power consumption due to no cache\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2524\" data-start=\"2470\"\u003e\n\t\u003cp data-end=\"2524\" data-start=\"2472\" style=\"text-align: justify;\"\u003eOptional \u003cstrong data-end=\"2506\" data-start=\"2481\"\u003eHPE Secure Encryption\u003c\/strong\u003e license support\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"HPE","offers":[{"title":"Default Title","offer_id":46466548498593,"sku":"779134-001","price":284.85,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2216\/8673\/files\/HPE-H240-12G-2-Port-SASSATA-Smart-Host-Bus-Adapter-HBA-726907-B21-779134-001.png?v=1779973113","url":"https:\/\/www.foxti.com.br\/products\/hpe-h240-12g-2-port-sassata-smart-host-bus-adapter-hba-726907-b21-779134-001","provider":"FoxTI","version":"1.0","type":"link"}