{"product_id":"dell-emc-384tb-nvme-u2-pcie-gen-30-x4-sff-25-ssd-kioxia-cd5-kcd5xlug3t84-017c57-17c57","title":"Dell EMC 3.84TB NVMe U.2 PCIe Gen 3.0 x4 SFF 2.5\" SSD Kioxia CD5 KCD5XLUG3T84 017C57 17C57","description":"\u003ch2 data-end=\"182\" data-section-id=\"1ub1kiz\" data-start=\"86\" style=\"text-align: justify;\"\u003eDell EMC 3.84TB NVMe U.2 PCIe Gen3 x4 SFF 2.5\" SSD Kioxia CD5 (KCD5XLUG3T84 \/ 017C57 \/ 17C57)\u003c\/h2\u003e\n\n\u003cp data-end=\"556\" data-start=\"184\" style=\"text-align: justify;\"\u003eThe Dell EMC 17C57 (Kioxia CD5 Series) is a Read Intensive (RI) enterprise NVMe SSD designed for high-capacity, read-heavy workloads such as data warehousing, media streaming, virtualization, and web-scale applications. Built with Kioxia BiCS FLASH 3D TLC NAND, it delivers high throughput, low latency, and enterprise-grade reliability in modern data center environments.\u003c\/p\u003e\n\n\u003chr data-end=\"561\" data-start=\"558\"\u003e\n\u003ch2 data-end=\"585\" data-section-id=\"1rh81ww\" data-start=\"563\" style=\"text-align: justify;\"\u003eCore Specifications\u003c\/h2\u003e\n\n\u003cul data-end=\"879\" data-start=\"587\"\u003e\n\t\u003cli data-end=\"611\" data-section-id=\"1apft0h\" data-start=\"587\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"602\" data-start=\"589\"\u003eCapacity:\u003c\/strong\u003e 3.84TB\u003c\/li\u003e\n\t\u003cli data-end=\"665\" data-section-id=\"xxobnb\" data-start=\"612\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"628\" data-start=\"614\"\u003eInterface:\u003c\/strong\u003e NVMe PCIe Gen 3.0 x4 (Single Port)\u003c\/li\u003e\n\t\u003cli data-end=\"719\" data-section-id=\"2msicu\" data-start=\"666\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"684\" data-start=\"668\"\u003eForm Factor:\u003c\/strong\u003e 2.5-inch SFF (U.2 \/ 15mm height)\u003c\/li\u003e\n\t\u003cli data-end=\"765\" data-section-id=\"1c43izo\" data-start=\"720\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"736\" data-start=\"722\"\u003eNAND Type:\u003c\/strong\u003e 64-layer BiCS FLASH 3D TLC\u003c\/li\u003e\n\t\u003cli data-end=\"810\" data-section-id=\"1ovkomc\" data-start=\"766\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"788\" data-start=\"768\"\u003eEndurance Class:\u003c\/strong\u003e Read Intensive (RI)\u003c\/li\u003e\n\t\u003cli data-end=\"847\" data-section-id=\"1sh8bar\" data-start=\"811\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"827\" data-start=\"813\"\u003eEndurance:\u003c\/strong\u003e ~1 DWPD (5 years)\u003c\/li\u003e\n\t\u003cli data-end=\"879\" data-section-id=\"1qyyt1r\" data-start=\"848\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"859\" data-start=\"850\"\u003eMTTF:\u003c\/strong\u003e 2.5 Million hours\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"884\" data-start=\"881\"\u003e\n\u003ch2 data-end=\"908\" data-section-id=\"2gccei\" data-start=\"886\" style=\"text-align: justify;\"\u003ePerformance Metrics\u003c\/h2\u003e\n\n\u003cul data-end=\"1120\" data-start=\"910\"\u003e\n\t\u003cli data-end=\"951\" data-section-id=\"1ag74a6\" data-start=\"910\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"932\" data-start=\"912\"\u003eSequential Read:\u003c\/strong\u003e Up to 3,140 MB\/s\u003c\/li\u003e\n\t\u003cli data-end=\"994\" data-section-id=\"12x04u9\" data-start=\"952\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"975\" data-start=\"954\"\u003eSequential Write:\u003c\/strong\u003e Up to 1,520 MB\/s\u003c\/li\u003e\n\t\u003cli data-end=\"1034\" data-section-id=\"vzdl3f\" data-start=\"995\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1013\" data-start=\"997\"\u003eRandom Read:\u003c\/strong\u003e Up to 465,000 IOPS\u003c\/li\u003e\n\t\u003cli data-end=\"1074\" data-section-id=\"89ko1j\" data-start=\"1035\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1054\" data-start=\"1037\"\u003eRandom Write:\u003c\/strong\u003e Up to 40,000 IOPS\u003c\/li\u003e\n\t\u003cli data-end=\"1120\" data-section-id=\"5o1rpw\" data-start=\"1075\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1099\" data-start=\"1077\"\u003ePower Consumption:\u003c\/strong\u003e 11W – 13W (Active)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1125\" data-start=\"1122\"\u003e\n\u003ch2 data-end=\"1142\" data-section-id=\"1ma7m6t\" data-start=\"1127\" style=\"text-align: justify;\"\u003eKey Features\u003c\/h2\u003e\n\n\u003cp data-end=\"1277\" data-start=\"1144\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1175\" data-start=\"1144\"\u003eRead-Optimized Performance:\u003c\/strong\u003e\u003cbr data-end=\"1178\" data-start=\"1175\"\u003e\nIdeal for workloads with high read demand such as analytics, content delivery, and virtualization\u003c\/p\u003e\n\n\u003cp data-end=\"1388\" data-start=\"1279\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1308\" data-start=\"1279\"\u003eAdvanced Data Protection:\u003c\/strong\u003e\u003cbr data-end=\"1311\" data-start=\"1308\"\u003e\nIncludes Power Loss Protection (PLP) and end-to-end data integrity features\u003c\/p\u003e\n\n\u003cp data-end=\"1501\" data-start=\"1390\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1421\" data-start=\"1390\"\u003eLow Latency NVMe Interface:\u003c\/strong\u003e\u003cbr data-end=\"1424\" data-start=\"1421\"\u003e\nPCIe Gen3 x4 interface ensures faster data access compared to SAS\/SATA SSDs\u003c\/p\u003e\n\n\u003cp data-end=\"1607\" data-start=\"1503\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1530\" data-start=\"1503\"\u003eEnterprise Reliability:\u003c\/strong\u003e\u003cbr data-end=\"1533\" data-start=\"1530\"\u003e\nDesigned for 24\/7 operation in mission-critical data center environments\u003c\/p\u003e\n\n\u003chr data-end=\"1612\" data-start=\"1609\"\u003e\n\u003ch2 data-end=\"1637\" data-section-id=\"wu5dvy\" data-start=\"1614\" style=\"text-align: justify;\"\u003eServer Compatibility\u003c\/h2\u003e\n\n\u003cp data-end=\"1746\" data-start=\"1639\" style=\"text-align: justify;\"\u003eThis SSD is designed for Dell PowerEdge servers and requires systems with NVMe (U.2 \/ SFF-8639) backplanes.\u003c\/p\u003e\n\n\u003chr data-end=\"1751\" data-start=\"1748\"\u003e\n\u003ch3 data-end=\"1782\" data-section-id=\"8rejbb\" data-start=\"1753\" style=\"text-align: justify;\"\u003ePowerEdge 16th Generation\u003c\/h3\u003e\n\n\u003cul data-end=\"1851\" data-start=\"1784\"\u003e\n\t\u003cli data-end=\"1800\" data-section-id=\"g84sa7\" data-start=\"1784\" style=\"text-align: justify;\"\u003eR660, R660xs\u003c\/li\u003e\n\t\u003cli data-end=\"1817\" data-section-id=\"1y8dxtb\" data-start=\"1801\" style=\"text-align: justify;\"\u003eR760, R760xs\u003c\/li\u003e\n\t\u003cli data-end=\"1834\" data-section-id=\"1xmrjwn\" data-start=\"1818\" style=\"text-align: justify;\"\u003eR6615, R6625\u003c\/li\u003e\n\t\u003cli data-end=\"1851\" data-section-id=\"269euf\" data-start=\"1835\" style=\"text-align: justify;\"\u003eR7615, R7625\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1856\" data-start=\"1853\"\u003e\n\u003ch3 data-end=\"1887\" data-section-id=\"1i4za5g\" data-start=\"1858\" style=\"text-align: justify;\"\u003ePowerEdge 15th Generation\u003c\/h3\u003e\n\n\u003cul data-end=\"1964\" data-start=\"1889\"\u003e\n\t\u003cli data-end=\"1905\" data-section-id=\"1hgwm5r\" data-start=\"1889\" style=\"text-align: justify;\"\u003eR650, R650xs\u003c\/li\u003e\n\t\u003cli data-end=\"1930\" data-section-id=\"jve1iy\" data-start=\"1906\" style=\"text-align: justify;\"\u003eR750, R750xs, R750xa\u003c\/li\u003e\n\t\u003cli data-end=\"1947\" data-section-id=\"cw852f\" data-start=\"1931\" style=\"text-align: justify;\"\u003eR6515, R6525\u003c\/li\u003e\n\t\u003cli data-end=\"1964\" data-section-id=\"pxwy9z\" data-start=\"1948\" style=\"text-align: justify;\"\u003eR7515, R7525\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1969\" data-start=\"1966\"\u003e\n\u003ch3 data-end=\"2000\" data-section-id=\"k1oryd\" data-start=\"1971\" style=\"text-align: justify;\"\u003ePowerEdge 14th Generation\u003c\/h3\u003e\n\n\u003cul data-end=\"2071\" data-start=\"2002\"\u003e\n\t\u003cli data-end=\"2024\" data-section-id=\"1x9u53o\" data-start=\"2002\" style=\"text-align: justify;\"\u003eR640, R740, R740xd\u003c\/li\u003e\n\t\u003cli data-end=\"2047\" data-section-id=\"1jpykf3\" data-start=\"2025\" style=\"text-align: justify;\"\u003eR840, R940, R940xa\u003c\/li\u003e\n\t\u003cli data-end=\"2071\" data-section-id=\"1szu59b\" data-start=\"2048\" style=\"text-align: justify;\"\u003eR6415, R7415, R7425\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2076\" data-start=\"2073\"\u003e\n\u003ch3 data-end=\"2134\" data-section-id=\"1e532c\" data-start=\"2078\" style=\"text-align: justify;\"\u003ePowerEdge 13th Generation (NVMe Configurations Only)\u003c\/h3\u003e\n\n\u003cul data-end=\"2158\" data-start=\"2136\"\u003e\n\t\u003cli data-end=\"2158\" data-section-id=\"fv2ldf\" data-start=\"2136\" style=\"text-align: justify;\"\u003eR630, R730, R730xd\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2163\" data-start=\"2160\"\u003e\n\u003ch2 data-end=\"2197\" data-section-id=\"ozh0ml\" data-start=\"2165\" style=\"text-align: justify;\"\u003eStorage \u0026amp; Array Compatibility\u003c\/h2\u003e\n\n\u003cul data-end=\"2347\" data-start=\"2199\"\u003e\n\t\u003cli data-end=\"2261\" data-section-id=\"178u1hl\" data-start=\"2199\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2226\" data-start=\"2201\"\u003ePowerVault ME Series:\u003c\/strong\u003e ME5024 (NVMe-configured systems)\u003c\/li\u003e\n\t\u003cli data-end=\"2347\" data-section-id=\"1h23odx\" data-start=\"2262\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2294\" data-start=\"2264\"\u003eNVMe Expansion Enclosures:\u003c\/strong\u003e Supported with compatible NVMe HBAs and backplanes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2352\" data-start=\"2349\"\u003e\n\u003ch2 data-end=\"2376\" data-section-id=\"12uqtvs\" data-start=\"2354\" style=\"text-align: justify;\"\u003eCompatibility Notes\u003c\/h2\u003e\n\n\u003cul data-end=\"2678\" data-start=\"2378\"\u003e\n\t\u003cli data-end=\"2424\" data-section-id=\"1fq4c09\" data-start=\"2378\" style=\"text-align: justify;\"\u003eRequires \u003cstrong data-end=\"2422\" data-start=\"2389\"\u003eNVMe U.2 (SFF-8639) backplane\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli data-end=\"2482\" data-section-id=\"1kjnq2k\" data-start=\"2425\" style=\"text-align: justify;\"\u003eNot compatible with standard SAS\/SATA-only backplanes\u003c\/li\u003e\n\t\u003cli data-end=\"2678\" data-section-id=\"es59ea\" data-start=\"2483\" style=\"text-align: justify;\"\u003eSupports enterprise operating systems including:\n\t\u003cul data-end=\"2678\" data-start=\"2538\"\u003e\n\t\t\u003cli data-end=\"2584\" data-section-id=\"1nobq43\" data-start=\"2538\"\u003eWindows Server (2012 R2, 2016, 2019, 2022)\u003c\/li\u003e\n\t\t\u003cli data-end=\"2602\" data-section-id=\"1ppgr79\" data-start=\"2587\"\u003eVMware ESXi\u003c\/li\u003e\n\t\t\u003cli data-end=\"2645\" data-section-id=\"1ip35ut\" data-start=\"2605\"\u003eRed Hat Enterprise Linux (RHEL 7.0+)\u003c\/li\u003e\n\t\t\u003cli data-end=\"2678\" data-section-id=\"ngmvtk\" data-start=\"2648\"\u003eModern Linux distributions\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2683\" data-start=\"2680\"\u003e\n\u003ch2 data-end=\"2708\" data-section-id=\"1p41egd\" data-start=\"2685\" style=\"text-align: justify;\"\u003eRelated Part Numbers\u003c\/h2\u003e\n\n\u003cul data-end=\"2764\" data-start=\"2710\"\u003e\n\t\u003cli data-end=\"2720\" data-section-id=\"ba0d27\" data-start=\"2710\" style=\"text-align: justify;\"\u003e017C57\u003c\/li\u003e\n\t\u003cli data-end=\"2730\" data-section-id=\"ppchin\" data-start=\"2721\" style=\"text-align: justify;\"\u003e17C57\u003c\/li\u003e\n\t\u003cli data-end=\"2747\" data-section-id=\"28hw0s\" data-start=\"2731\" style=\"text-align: justify;\"\u003eKCD5XLUG3T84\u003c\/li\u003e\n\t\u003cli data-end=\"2764\" data-section-id=\"33psx1\" data-start=\"2748\" style=\"text-align: justify;\"\u003eSDFPF84DAB01\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2769\" data-start=\"2766\"\u003e\n\u003cp data-end=\"3018\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"2771\" style=\"text-align: justify;\"\u003eThe Dell EMC 3.84TB NVMe U.2 SSD (Kioxia CD5 Series) delivers high-speed performance, strong endurance, and enterprise-grade reliability, making it an excellent solution for read-intensive workloads in modern NVMe-enabled data center environments.\u003c\/p\u003e\n","brand":"Dell","offers":[{"title":"Default Title","offer_id":46466181300385,"sku":"17C57","price":19154.85,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2216\/8673\/files\/Dell-EMC-3_84TB-NVMe-U_2-PCIe-Gen-3_0-x4-SFF-2_5-SSD-Kioxia-CD5-KCD5XLUG3T84-017C57-17C57.png?v=1779963097","url":"https:\/\/www.foxti.com.br\/products\/dell-emc-384tb-nvme-u2-pcie-gen-30-x4-sff-25-ssd-kioxia-cd5-kcd5xlug3t84-017c57-17c57","provider":"FoxTI","version":"1.0","type":"link"}