{"product_id":"dell-2tb-nvme-u2-pcie-g3-x4-25-ssd-intel-dc-p4510-ssdpe2kx020t8t-09h31j-9h31j","title":"Dell 2TB NVMe U.2 PCIe G3 x4 2.5\" SSD Intel DC P4510 SSDPE2KX020T8T 09H31J 9H31J","description":"\u003ch2 data-end=\"59\" data-start=\"0\" style=\"text-align: justify;\"\u003eDell 2TB NVMe U.2 PCIe Gen3 x4 2.5\" SSD Intel DC P4510\u003c\/h2\u003e\n\n\u003cp data-end=\"495\" data-start=\"61\" style=\"text-align: justify;\"\u003eThe \u003cstrong data-end=\"104\" data-start=\"65\"\u003eDell 2TB NVMe U.2 PCIe SSD (09H31J)\u003c\/strong\u003e is an enterprise-class solid-state drive based on the \u003cstrong data-end=\"184\" data-start=\"159\"\u003eIntel DC P4510 series\u003c\/strong\u003e, designed for high-performance data center workloads such as virtualization, cloud infrastructure, and database environments. Built with 64-layer 3D TLC NAND and a PCIe Gen3 x4 NVMe interface, this drive delivers high throughput, low latency, and strong endurance for demanding enterprise storage environments.\u003c\/p\u003e\n\n\u003chr data-end=\"500\" data-start=\"497\"\u003e\n\u003ch2 data-end=\"524\" data-start=\"502\" style=\"text-align: justify;\"\u003eCore Specifications\u003c\/h2\u003e\n\n\u003cul data-end=\"936\" data-start=\"526\"\u003e\n\t\u003cli data-end=\"547\" data-start=\"526\"\u003e\n\t\u003cp data-end=\"547\" data-start=\"528\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"541\" data-start=\"528\"\u003eCapacity:\u003c\/strong\u003e 2TB\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"593\" data-start=\"548\"\u003e\n\t\u003cp data-end=\"593\" data-start=\"550\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"567\" data-start=\"550\"\u003eManufacturer:\u003c\/strong\u003e Intel (DC P4510 Series)\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"634\" data-start=\"594\"\u003e\n\t\u003cp data-end=\"634\" data-start=\"596\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"617\" data-start=\"596\"\u003eDell Part Number:\u003c\/strong\u003e 09H31J \/ 9H31J\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"671\" data-start=\"635\"\u003e\n\t\u003cp data-end=\"671\" data-start=\"637\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"654\" data-start=\"637\"\u003eModel Number:\u003c\/strong\u003e SSDPE2KX020T8T\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"739\" data-start=\"672\"\u003e\n\t\u003cp data-end=\"739\" data-start=\"674\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"690\" data-start=\"674\"\u003eForm Factor:\u003c\/strong\u003e 2.5-inch Small Form Factor (SFF) – 15mm height\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"796\" data-start=\"740\"\u003e\n\t\u003cp data-end=\"796\" data-start=\"742\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"756\" data-start=\"742\"\u003eInterface:\u003c\/strong\u003e PCIe 3.0 x4 NVMe (NVMe 1.2 compliant)\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"830\" data-start=\"797\"\u003e\n\t\u003cp data-end=\"830\" data-start=\"799\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"813\" data-start=\"799\"\u003eConnector:\u003c\/strong\u003e U.2 (SFF-8639)\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"866\" data-start=\"831\"\u003e\n\t\u003cp data-end=\"866\" data-start=\"833\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"848\" data-start=\"833\"\u003eNAND Flash:\u003c\/strong\u003e 64-Layer 3D TLC\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"896\" data-start=\"867\"\u003e\n\t\u003cp data-end=\"896\" data-start=\"869\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"878\" data-start=\"869\"\u003eMTBF:\u003c\/strong\u003e 2 Million Hours\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"936\" data-start=\"897\"\u003e\n\t\u003cp data-end=\"936\" data-start=\"899\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"920\" data-start=\"899\"\u003eShock Resistance:\u003c\/strong\u003e 1000 G (0.5 ms)\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"941\" data-start=\"938\"\u003e\n\u003ch2 data-end=\"972\" data-start=\"943\" style=\"text-align: justify;\"\u003ePerformance Specifications\u003c\/h2\u003e\n\n\u003cul data-end=\"1259\" data-start=\"974\"\u003e\n\t\u003cli data-end=\"1021\" data-start=\"974\"\u003e\n\t\u003cp data-end=\"1021\" data-start=\"976\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1002\" data-start=\"976\"\u003eSequential Read Speed:\u003c\/strong\u003e Up to 3,200 MB\/s\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1109\" data-start=\"1022\"\u003e\n\t\u003cp data-end=\"1109\" data-start=\"1024\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1051\" data-start=\"1024\"\u003eSequential Write Speed:\u003c\/strong\u003e Up to 3,000 MB\/s (some Dell variants up to ~1,600 MB\/s)\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1154\" data-start=\"1110\"\u003e\n\t\u003cp data-end=\"1154\" data-start=\"1112\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1133\" data-start=\"1112\"\u003eRandom Read (4K):\u003c\/strong\u003e Up to 637,000 IOPS\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1200\" data-start=\"1155\"\u003e\n\t\u003cp data-end=\"1200\" data-start=\"1157\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1179\" data-start=\"1157\"\u003eRandom Write (4K):\u003c\/strong\u003e Up to 139,000 IOPS\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1229\" data-start=\"1201\"\u003e\n\t\u003cp data-end=\"1229\" data-start=\"1203\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1220\" data-start=\"1203\"\u003eRead Latency:\u003c\/strong\u003e ~10 µs\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1259\" data-start=\"1230\"\u003e\n\t\u003cp data-end=\"1259\" data-start=\"1232\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1250\" data-start=\"1232\"\u003eWrite Latency:\u003c\/strong\u003e ~18 µs\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp data-end=\"1417\" data-start=\"1261\" style=\"text-align: justify;\"\u003eThese performance characteristics make the drive suitable for virtualization clusters, high-performance databases, and high-speed enterprise storage arrays.\u003c\/p\u003e\n\n\u003chr data-end=\"1422\" data-start=\"1419\"\u003e\n\u003ch2 data-end=\"1450\" data-start=\"1424\" style=\"text-align: justify;\"\u003eReliability \u0026amp; Endurance\u003c\/h2\u003e\n\n\u003cul data-end=\"1690\" data-start=\"1452\"\u003e\n\t\u003cli data-end=\"1524\" data-start=\"1452\"\u003e\n\t\u003cp data-end=\"1524\" data-start=\"1454\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1475\" data-start=\"1454\"\u003eEndurance Rating:\u003c\/strong\u003e Up to 1 Drive Write Per Day (DWPD) for 5 years\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1615\" data-start=\"1525\"\u003e\n\t\u003cp data-end=\"1615\" data-start=\"1527\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1553\" data-start=\"1527\"\u003ePower Loss Protection:\u003c\/strong\u003e Enhanced power-loss data protection with onboard capacitors\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1690\" data-start=\"1616\"\u003e\n\t\u003cp data-end=\"1690\" data-start=\"1618\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1637\" data-start=\"1618\"\u003eData Integrity:\u003c\/strong\u003e Enterprise-grade firmware and ECC error protection\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp data-end=\"1793\" data-start=\"1692\" style=\"text-align: justify;\"\u003eThe integrated power-loss protection safeguards in-flight data during unexpected power interruptions.\u003c\/p\u003e\n\n\u003chr data-end=\"1798\" data-start=\"1795\"\u003e\n\u003ch2 data-end=\"1820\" data-start=\"1800\" style=\"text-align: justify;\"\u003ePower Consumption\u003c\/h2\u003e\n\n\u003cul data-end=\"1901\" data-start=\"1822\"\u003e\n\t\u003cli data-end=\"1859\" data-start=\"1822\"\u003e\n\t\u003cp data-end=\"1859\" data-start=\"1824\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1841\" data-start=\"1824\"\u003eActive Power:\u003c\/strong\u003e Up to ~16 Watts\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1901\" data-start=\"1860\"\u003e\n\t\u003cp data-end=\"1901\" data-start=\"1862\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1877\" data-start=\"1862\"\u003eIdle Power:\u003c\/strong\u003e Approximately 5 Watts\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1906\" data-start=\"1903\"\u003e\n\u003ch2 data-end=\"1934\" data-start=\"1908\" style=\"text-align: justify;\"\u003ePhysical Specifications\u003c\/h2\u003e\n\n\u003cul data-end=\"2019\" data-start=\"1936\"\u003e\n\t\u003cli data-end=\"1974\" data-start=\"1936\"\u003e\n\t\u003cp data-end=\"1974\" data-start=\"1938\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1954\" data-start=\"1938\"\u003eForm Factor:\u003c\/strong\u003e 2.5\" U.2 NVMe SSD\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1996\" data-start=\"1975\"\u003e\n\t\u003cp data-end=\"1996\" data-start=\"1977\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1988\" data-start=\"1977\"\u003eHeight:\u003c\/strong\u003e 15 mm\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2019\" data-start=\"1997\"\u003e\n\t\u003cp data-end=\"2019\" data-start=\"1999\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2010\" data-start=\"1999\"\u003eWeight:\u003c\/strong\u003e ~139 g\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp data-end=\"2163\" data-start=\"2021\" style=\"text-align: justify;\"\u003eBecause this is a \u003cstrong data-end=\"2064\" data-start=\"2039\"\u003e15mm enterprise drive\u003c\/strong\u003e, it requires a compatible 2.5\" NVMe drive bay and will not fit in thinner laptop or consumer bays.\u003c\/p\u003e\n\n\u003chr data-end=\"2168\" data-start=\"2165\"\u003e\n\u003ch2 data-end=\"2208\" data-start=\"2170\" style=\"text-align: justify;\"\u003eDell PowerEdge Server Compatibility\u003c\/h2\u003e\n\n\u003cp data-end=\"2341\" data-start=\"2210\" style=\"text-align: justify;\"\u003eThe Dell-branded firmware (09H31J) is validated for many \u003cstrong data-end=\"2293\" data-start=\"2267\"\u003eDell PowerEdge servers\u003c\/strong\u003e, particularly those supporting NVMe backplanes.\u003c\/p\u003e\n\n\u003ch3 data-end=\"2386\" data-start=\"2343\" style=\"text-align: justify;\"\u003e14th Generation PowerEdge (Recommended)\u003c\/h3\u003e\n\n\u003cul data-end=\"2533\" data-start=\"2388\"\u003e\n\t\u003cli data-end=\"2411\" data-start=\"2388\"\u003e\n\t\u003cp data-end=\"2411\" data-start=\"2390\" style=\"text-align: justify;\"\u003eDell PowerEdge R640\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2435\" data-start=\"2412\"\u003e\n\t\u003cp data-end=\"2435\" data-start=\"2414\" style=\"text-align: justify;\"\u003eDell PowerEdge R740\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2461\" data-start=\"2436\"\u003e\n\t\u003cp data-end=\"2461\" data-start=\"2438\" style=\"text-align: justify;\"\u003eDell PowerEdge R740xd\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2485\" data-start=\"2462\"\u003e\n\t\u003cp data-end=\"2485\" data-start=\"2464\" style=\"text-align: justify;\"\u003eDell PowerEdge R940\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2509\" data-start=\"2486\"\u003e\n\t\u003cp data-end=\"2509\" data-start=\"2488\" style=\"text-align: justify;\"\u003eDell PowerEdge T440\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2533\" data-start=\"2510\"\u003e\n\t\u003cp data-end=\"2533\" data-start=\"2512\" style=\"text-align: justify;\"\u003eDell PowerEdge T640\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"2564\" data-start=\"2535\" style=\"text-align: justify;\"\u003eModular \/ Blade Platforms\u003c\/h3\u003e\n\n\u003cul data-end=\"2613\" data-start=\"2566\"\u003e\n\t\u003cli data-end=\"2588\" data-start=\"2566\"\u003e\n\t\u003cp data-end=\"2588\" data-start=\"2568\" style=\"text-align: justify;\"\u003eDell PowerEdge FX2\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2613\" data-start=\"2589\"\u003e\n\t\u003cp data-end=\"2613\" data-start=\"2591\" style=\"text-align: justify;\"\u003eDell PowerEdge FD332\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"2642\" data-start=\"2615\" style=\"text-align: justify;\"\u003e15th Generation Example\u003c\/h3\u003e\n\n\u003cul data-end=\"2669\" data-start=\"2644\"\u003e\n\t\u003cli data-end=\"2669\" data-start=\"2644\"\u003e\n\t\u003cp data-end=\"2669\" data-start=\"2646\" style=\"text-align: justify;\"\u003eDell PowerEdge R750xs\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 data-end=\"2729\" data-start=\"2671\" style=\"text-align: justify;\"\u003e13th Generation (Optional NVMe configuration required)\u003c\/h3\u003e\n\n\u003cul data-end=\"2778\" data-start=\"2731\"\u003e\n\t\u003cli data-end=\"2754\" data-start=\"2731\"\u003e\n\t\u003cp data-end=\"2754\" data-start=\"2733\" style=\"text-align: justify;\"\u003eDell PowerEdge R630\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2778\" data-start=\"2755\"\u003e\n\t\u003cp data-end=\"2778\" data-start=\"2757\" style=\"text-align: justify;\"\u003eDell PowerEdge R730\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp data-end=\"2887\" data-start=\"2780\" style=\"text-align: justify;\"\u003eThese systems require NVMe-enabled backplanes and PCIe extender cables when configured for U.2 NVMe drives.\u003c\/p\u003e\n\n\u003chr data-end=\"2892\" data-start=\"2889\"\u003e\n\u003ch2 data-end=\"2929\" data-start=\"2894\" style=\"text-align: justify;\"\u003eCross-Brand Server Compatibility\u003c\/h2\u003e\n\n\u003cp data-end=\"3060\" data-start=\"2931\" style=\"text-align: justify;\"\u003eBecause the drive is based on the \u003cstrong data-end=\"2992\" data-start=\"2965\"\u003eIntel DC P4510 platform\u003c\/strong\u003e, it can also be used in other enterprise servers with NVMe support:\u003c\/p\u003e\n\n\u003cul data-end=\"3296\" data-start=\"3062\"\u003e\n\t\u003cli data-end=\"3164\" data-start=\"3062\"\u003e\n\t\u003cp data-end=\"3164\" data-start=\"3064\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"3081\" data-start=\"3064\"\u003eHPE ProLiant:\u003c\/strong\u003e NVMe-enabled Gen10 \/ Gen11 systems such as DL360 and DL380 with Express Bay kits\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"3228\" data-start=\"3165\"\u003e\n\t\u003cp data-end=\"3228\" data-start=\"3167\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"3190\" data-start=\"3167\"\u003eLenovo ThinkSystem:\u003c\/strong\u003e NVMe systems such as SR630 or SR650\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"3296\" data-start=\"3229\"\u003e\n\t\u003cp data-end=\"3296\" data-start=\"3231\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"3254\" data-start=\"3231\"\u003eSupermicro Servers:\u003c\/strong\u003e Any system with NVMe-enabled backplanes\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp data-end=\"3418\" data-start=\"3298\" style=\"text-align: justify;\"\u003eNon-Dell systems may function normally but may not display full Dell-specific telemetry through system management tools.\u003c\/p\u003e\n\n\u003chr data-end=\"3423\" data-start=\"3420\"\u003e\n\u003ch2 data-end=\"3463\" data-start=\"3425\" style=\"text-align: justify;\"\u003eWorkstation \u0026amp; Desktop Compatibility\u003c\/h2\u003e\n\n\u003cp data-end=\"3561\" data-start=\"3465\" style=\"text-align: justify;\"\u003eThis U.2 NVMe drive can also be used in workstations or desktop systems with the proper adapter:\u003c\/p\u003e\n\n\u003cul data-end=\"3817\" data-start=\"3563\"\u003e\n\t\u003cli data-end=\"3635\" data-start=\"3563\"\u003e\n\t\u003cp data-end=\"3635\" data-start=\"3565\" style=\"text-align: justify;\"\u003eRequires a \u003cstrong data-end=\"3604\" data-start=\"3576\"\u003eU.2 to PCIe adapter card\u003c\/strong\u003e or compatible NVMe backplane\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"3817\" data-start=\"3636\"\u003e\n\t\u003cp data-end=\"3676\" data-start=\"3638\" style=\"text-align: justify;\"\u003eSupported operating systems include:\u003c\/p\u003e\n\n\t\u003cul data-end=\"3817\" data-start=\"3679\"\u003e\n\t\t\u003cli data-end=\"3726\" data-start=\"3679\"\u003e\n\t\t\u003cp data-end=\"3726\" data-start=\"3681\" style=\"text-align: justify;\"\u003eMicrosoft Windows Server 2016 \/ 2019 \/ 2022\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"3761\" data-start=\"3729\"\u003e\n\t\t\u003cp data-end=\"3761\" data-start=\"3731\" style=\"text-align: justify;\"\u003eVMware ESXi 6.5 U2 and newer\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"3797\" data-start=\"3764\"\u003e\n\t\t\u003cp data-end=\"3797\" data-start=\"3766\" style=\"text-align: justify;\"\u003eRed Hat Enterprise Linux 7.6+\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\t\u003cli data-end=\"3817\" data-start=\"3800\"\u003e\n\t\t\u003cp data-end=\"3817\" data-start=\"3802\" style=\"text-align: justify;\"\u003eUbuntu 18.04.2+\u003c\/p\u003e\n\t\t\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"3822\" data-start=\"3819\"\u003e\n\u003ch2 data-end=\"3857\" data-start=\"3824\" style=\"text-align: justify;\"\u003eCritical Hardware Requirements\u003c\/h2\u003e\n\n\u003cp data-end=\"3925\" data-start=\"3859\" style=\"text-align: justify;\"\u003eTo use this SSD properly, the system must meet these requirements:\u003c\/p\u003e\n\n\u003cul data-end=\"4076\" data-start=\"3927\"\u003e\n\t\u003cli data-end=\"4004\" data-start=\"3927\"\u003e\n\t\u003cp data-end=\"4004\" data-start=\"3929\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"3955\" data-start=\"3929\"\u003eNVMe-enabled backplane\u003c\/strong\u003e (SATA\/SAS-only bays will not detect the drive)\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"4045\" data-start=\"4005\"\u003e\n\t\u003cp data-end=\"4045\" data-start=\"4007\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"4043\" data-start=\"4007\"\u003eU.2 \/ SFF-8639 connector support\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"4076\" data-start=\"4046\"\u003e\n\t\u003cp data-end=\"4076\" data-start=\"4048\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"4076\" data-start=\"4048\"\u003e15mm drive bay clearance\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"4081\" data-start=\"4078\"\u003e\n\u003ch2 data-end=\"4112\" data-start=\"4083\" style=\"text-align: justify;\"\u003eOther Related Part Numbers\u003c\/h2\u003e\n\n\u003cp data-end=\"4183\" data-start=\"4114\" style=\"text-align: justify;\"\u003eThis enterprise SSD may also appear under the following part numbers:\u003c\/p\u003e\n\n\u003cul data-end=\"4234\" data-start=\"4185\"\u003e\n\t\u003cli data-end=\"4207\" data-start=\"4185\"\u003e\n\t\u003cp data-end=\"4207\" data-start=\"4187\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"4205\" data-start=\"4187\"\u003eSSDPE2KX020T8T\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"4222\" data-start=\"4208\"\u003e\n\t\u003cp data-end=\"4222\" data-start=\"4210\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"4220\" data-start=\"4210\"\u003e09H31J\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"4234\" data-start=\"4223\"\u003e\n\t\u003cp data-end=\"4234\" data-start=\"4225\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"4234\" data-start=\"4225\"\u003e9H31J\u003c\/strong\u003e\u003c\/p\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp data-end=\"4442\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"4236\" style=\"text-align: justify;\"\u003eThese identifiers may represent Dell OEM firmware versions or Intel manufacturing model numbers, but they refer to the same \u003cstrong data-end=\"4415\" data-start=\"4360\"\u003e2TB Intel DC P4510 U.2 NVMe enterprise SSD platform\u003c\/strong\u003e when specifications match.\u003c\/p\u003e\n","brand":"Intel","offers":[{"title":"Default Title","offer_id":46466013397153,"sku":"9H31J","price":5699.85,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2216\/8673\/files\/Dell-2TB-NVMe-U_2-PCIe-G3-x4-2_5-SSD-Intel-DC-P4510-SSDPE2KX020T8T-09H31J-9H31J.png?v=1779951603","url":"https:\/\/www.foxti.com.br\/products\/dell-2tb-nvme-u2-pcie-g3-x4-25-ssd-intel-dc-p4510-ssdpe2kx020t8t-09h31j-9h31j","provider":"FoxTI","version":"1.0","type":"link"}