{"product_id":"atv212hd11n4-altivar-212-vfd-15-hp225-amps-400480-vac-three-phase-inputthree-phase-output-ip20-housing-replaces-the-altivar21-square-d","title":"ATV212HD11N4 | Altivar 212 VFD, 15 hp\/22.5 amps, 400\/480 VAC Three Phase Input\/Three Phase Output, IP20 Housing (Replaces the Altivar21) | Square D","description":"\u003cspan style=\"color:red;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e  \u003cp\u003e\u003cb\u003eAltivar 212 VFD, 15 hp\/22.5 amps, 400\/480 VAC Three Phase Input\/Three Phase Output, IP20 Housing (Replaces the Altivar21)\u003c\/b\u003e\u003c\/p\u003e \u003cb\u003eAltivar 212 VFD\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e15 HP\u003c\/li\u003e\n\u003cli\u003eContinuous Output Current: 22.5 amps\u003c\/li\u003e\n\u003cli\u003eAC Line Input Line Voltage: 380\/480 VAC Three Phase Input\/Output\u003c\/li\u003e\n\u003cli\u003eEnclosure Rating: IP20\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003cbr\u003eThe Alitvar 212 drive includes: \u003cul\u003e\n\u003cli\u003e3 logic inputs\u003c\/li\u003e\n\u003cli\u003e2 analog inputs\u003c\/li\u003e\n\u003cli\u003e1 analog output\u003c\/li\u003e\n\u003cli\u003e2 relay outputs (with 1 NO and 1 NO\/NC contacts)\u003c\/li\u003e\n\u003cli\u003eIntegrated 4 digit, 7-segment LED display with a 7 button keypad\u003c\/li\u003e\n\u003cli\u003eRJ45 Modbus port plus a four-screw terminal block for BACnet, Modbus, Metasys N2 and Apogee P1 communication protocols\u003c\/li\u003e\n\u003cli\u003eLonWorks is available in an option card\u003cul\u003e This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 11kW \/ 15hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 6.45kg and its dimensions are, 180mm wide, 232mm high, 170mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC\/EN 61800-5-1 and IEC\/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+\/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet. It is eco-friendly and complies with directives such as RoHS, WEEE, etc.relating to environmental protection.\u003cdl\u003e\n\u003cdt\u003edevice short name\u003c\/dt\u003e\n\u003cdd\u003eATV212\u003c\/dd\u003e\n\u003cdt\u003eproduct destination\u003c\/dt\u003e\n\u003cdd\u003eAsynchronous motors\u003c\/dd\u003e\n\u003cdt\u003ePhase\u003c\/dt\u003e\n\u003cdd\u003e3 phase\u003c\/dd\u003e\n\u003cdt\u003emotor power kW\u003c\/dt\u003e\n\u003cdd\u003e11 kW\u003c\/dd\u003e\n\u003cdt\u003eMaximum Horse Power Rating\u003c\/dt\u003e\n\u003cdd\u003e15 hp\u003c\/dd\u003e\n\u003cdt\u003esupply voltage limits\u003c\/dt\u003e\n\u003cdd\u003e323…528 V\u003c\/dd\u003e\n\u003cdt\u003esupply frequency\u003c\/dt\u003e\n\u003cdd\u003e50...60 Hz - 5...5 %\u003c\/dd\u003e\n\u003cdt\u003eline current\u003c\/dt\u003e\n\u003cdd\u003e16.8 A 480 V;21.1 A 380 V\u003c\/dd\u003e\n\u003cdt\u003eRange of Product\u003c\/dt\u003e\n\u003cdd\u003eAltivar 212\u003c\/dd\u003e\n\u003cdt\u003eProduct or Component Type\u003c\/dt\u003e\n\u003cdd\u003eVariable speed drive\u003c\/dd\u003e\n\u003cdt\u003eProduct Specific Application\u003c\/dt\u003e\n\u003cdd\u003ePumps and fans in HVAC\u003c\/dd\u003e\n\u003cdt\u003eCommunication Port Protocol\u003c\/dt\u003e\n\u003cdd\u003eMETASYS N2;APOGEE FLN;LonWorks;BACnet;Modbus\u003c\/dd\u003e\n\u003cdt\u003e[Us] rated supply voltage\u003c\/dt\u003e\n\u003cdd\u003e380...480 V - 15...10 %\u003c\/dd\u003e\n\u003cdt\u003eEMC filter\u003c\/dt\u003e\n\u003cdd\u003eClass C2 EMC filter integrated\u003c\/dd\u003e\n\u003cdt\u003eIP degree of protection\u003c\/dt\u003e\n\u003cdd\u003eIP21\u003c\/dd\u003e\n\u003cdt\u003eapparent power\u003c\/dt\u003e\n\u003cdd\u003e17.1 kVA 380 V\u003c\/dd\u003e\n\u003cdt\u003econtinuous output current\u003c\/dt\u003e\n\u003cdd\u003e22.5 A 380 V;22.5 A 460 V\u003c\/dd\u003e\n\u003cdt\u003emaximum transient current\u003c\/dt\u003e\n\u003cdd\u003e24.8 A 60 s\u003c\/dd\u003e\n\u003cdt\u003espeed drive output frequency\u003c\/dt\u003e\n\u003cdd\u003e0.5…200 Hz\u003c\/dd\u003e\n\u003cdt\u003espeed range\u003c\/dt\u003e\n\u003cdd\u003e1…10\u003c\/dd\u003e\n\u003cdt\u003espeed accuracy\u003c\/dt\u003e\n\u003cdd\u003e+\/- 10 % of nominal slip 0.2 Tn to Tn\u003c\/dd\u003e\n\u003cdt\u003elocal signalling\u003c\/dt\u003e\n\u003cdd\u003efor DC bus energized 1 LED (red)\u003c\/dd\u003e\n\u003cdt\u003eoutput voltage\u003c\/dt\u003e\n\u003cdd\u003e\u0026lt;= power supply voltage\u003c\/dd\u003e\n\u003cdt\u003eisolation\u003c\/dt\u003e\n\u003cdd\u003eElectrical between power and control\u003c\/dd\u003e\n\u003cdt\u003etype of cable\u003c\/dt\u003e\n\u003cdd\u003eWithout mounting kit 1 IEC cable 113 °F (45 °C);copper 90 °C \/ XLPE\/EPR;Without mounting kit 1 IEC cable 113 °F (45 °C);copper 70 °C \/ PVC;With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C);copper 75 °C \/ PVC\u003c\/dd\u003e\n\u003cdt\u003eelectrical connection\u003c\/dt\u003e\n\u003cdd\u003eVIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES terminal 0.00 in² (2.5 mm²) \/ AWG 14;L1\/R;L2\/S;L3\/T terminal 0.02 in² (16 mm²) \/ AWG 6\u003c\/dd\u003e\n\u003cdt\u003etightening torque\u003c\/dt\u003e\n\u003cdd\u003e5.31 lbf.in (0.6 N.m) VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES);22.13 lbf.in (2.5 N.m);22 lb.in L1\/R;L2\/S;L3\/T)\u003c\/dd\u003e\n\u003cdt\u003esupply\u003c\/dt\u003e\n\u003cdd\u003eInternal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +\/- 5 %;\u0026lt;10 A overload and short-circuit protection;Internal supply 24 V DC 21…27 V);\u0026lt;200 A overload and short-circuit protection\u003c\/dd\u003e\n\u003cdt\u003esampling duration\u003c\/dt\u003e\n\u003cdd\u003e2 ms +\/- 0.5 ms F discrete;2 ms +\/- 0.5 ms R discrete;2 ms +\/- 0.5 ms RES discrete;3.5 ms +\/- 0.5 ms VIA analog;22 ms +\/- 0.5 ms VIB analog\u003c\/dd\u003e\n\u003cdt\u003eresponse time\u003c\/dt\u003e\n\u003cdd\u003eFM 2 ms +\/- 0.5 ms analog;FLA;FLC 7 ms +\/- 0.5 ms discrete;FLB;FLC 7 ms +\/- 0.5 ms discrete;RY;RC 7 ms +\/- 0.5 ms discrete\u003c\/dd\u003e\n\u003cdt\u003eaccuracy\u003c\/dt\u003e\n\u003cdd\u003e+\/- 0.6 % VIA) for a temperature variation 60 °C;+\/- 0.6 % VIB) for a temperature variation 60 °C;+\/- 1 % FM) for a temperature variation 60 °C\u003c\/dd\u003e\n\u003cdt\u003elinearity error\u003c\/dt\u003e\n\u003cdd\u003eVIA +\/- 0.15 % of maximum value input;VIB +\/- 0.15 % of maximum value input;FM +\/- 0.2 % output\u003c\/dd\u003e\n\u003cdt\u003eanalogue output type\u003c\/dt\u003e\n\u003cdd\u003eFM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits;FM switch-configurable current 0...20 mA 970 Ohm 10 bits\u003c\/dd\u003e\n\u003cdt\u003ediscrete output type\u003c\/dt\u003e\n\u003cdd\u003eConfigurable relay logic FLA;FLC) NO - 100000 cycles;Configurable relay logic FLB;FLC) NC - 100000 cycles;Configurable relay logic RY;RC) NO - 100000 cycles\u003c\/dd\u003e\n\u003cdt\u003eminimum switching current\u003c\/dt\u003e\n\u003cdd\u003e3 mA 24 V DC configurable relay logic\u003c\/dd\u003e\n\u003cdt\u003emaximum switching current\u003c\/dt\u003e\n\u003cdd\u003e5 A 250 V AC resistive cos phi = 1 L\/R = 0 ms FL;R);5 A 30 V DC resistive cos phi = 1 L\/R = 0 ms FL;R);2 A 250 V AC inductive cos phi = 0.4 L\/R = 7 ms FL;R);2 A 30 V DC inductive cos phi = 0.4 L\/R = 7 ms FL;R)\u003c\/dd\u003e\n\u003cdt\u003ediscrete input type\u003c\/dt\u003e\n\u003cdd\u003eF programmable 24 V DC level 1 PLC 4700 Ohm;R programmable 24 V DC level 1 PLC 4700 Ohm;RES programmable 24 V DC level 1 PLC 4700 Ohm\u003c\/dd\u003e\n\u003cdt\u003ediscrete input logic\u003c\/dt\u003e\n\u003cdd\u003ePositive logic (source) F;R;RES);\u0026lt;= 5 V;\u0026gt;= 11 V;Negative logic (sink) F;R;RES);\u0026gt;= 16 V;\u0026lt;= 10 V\u003c\/dd\u003e\n\u003cdt\u003edielectric strength\u003c\/dt\u003e\n\u003cdd\u003e3535 V DC between earth and power terminals;5092 V DC between control and power terminals\u003c\/dd\u003e\n\u003cdt\u003einsulation resistance\u003c\/dt\u003e\n\u003cdd\u003e\u0026gt;= 1 mOhm 500 V DC for 1 minute\u003c\/dd\u003e\n\u003cdt\u003efrequency resolution\u003c\/dt\u003e\n\u003cdd\u003eDisplay unit 0.1 Hz;Analog input 0.024\/50 Hz\u003c\/dd\u003e\n\u003cdt\u003eCommunication Service\u003c\/dt\u003e\n\u003cdd\u003eRead holding registers (03) 2 words maximum;Time out setting from 0.1 to 100 s;Write single register (06);Monitoring inhibitable;Write multiple registers (16) 2 words maximum;Read device identification (43)\u003c\/dd\u003e\n\u003cdt\u003eoption card\u003c\/dt\u003e\n\u003cdd\u003eCommunication card LonWorks\u003c\/dd\u003e\n\u003cdt\u003epower dissipation in W\u003c\/dt\u003e\n\u003cdd\u003e430 W\u003c\/dd\u003e\n\u003cdt\u003eair flow\u003c\/dt\u003e\n\u003cdd\u003e38833.99 Gal\/hr(US) (147 m3\/h)\u003c\/dd\u003e\n\u003cdt\u003efunctionality\u003c\/dt\u003e\n\u003cdd\u003eMid\u003c\/dd\u003e\n\u003cdt\u003especific application\u003c\/dt\u003e\n\u003cdd\u003eHVAC\u003c\/dd\u003e\n\u003cdt\u003eVariable speed drive application selection\u003c\/dt\u003e\n\u003cdd\u003eCompressor for scroll Building - HVAC;Fan Building - HVAC;Pump Building - HVAC\u003c\/dd\u003e\n\u003cdt\u003eMotor power range AC-3\u003c\/dt\u003e\n\u003cdd\u003e7…11 kW 380…440 V 3 phase;7…11 kW 480…500 V 3 phase\u003c\/dd\u003e\n\u003cdt\u003emotor starter type\u003c\/dt\u003e\n\u003cdd\u003eVariable speed drive\u003c\/dd\u003e\n\u003cdt\u003ediscrete output number\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003cdt\u003eanalogue input number\u003c\/dt\u003e\n\u003cdd\u003e2\u003c\/dd\u003e\n\u003cdt\u003eanalogue input type\u003c\/dt\u003e\n\u003cdd\u003eVIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable PTC probe 0...6 probes 1500 Ohm;VIA switch-configurable current 0...20 mA 250 Ohm 10 bits\u003c\/dd\u003e\n\u003cdt\u003eanalogue output number\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003cdt\u003ephysical interface\u003c\/dt\u003e\n\u003cdd\u003e2-wire RS 485\u003c\/dd\u003e\n\u003cdt\u003eConnector Type\u003c\/dt\u003e\n\u003cdd\u003e1 open style;1 RJ45\u003c\/dd\u003e\n\u003cdt\u003eTransmission Rate\u003c\/dt\u003e\n\u003cdd\u003e9600 bps or 19200 bps\u003c\/dd\u003e\n\u003cdt\u003etransmission frame\u003c\/dt\u003e\n\u003cdd\u003eRTU\u003c\/dd\u003e\n\u003cdt\u003enumber of addresses\u003c\/dt\u003e\n\u003cdd\u003e1…247\u003c\/dd\u003e\n\u003cdt\u003edata format\u003c\/dt\u003e\n\u003cdd\u003e8 bits;1 stop;odd even or no configurable parity\u003c\/dd\u003e\n\u003cdt\u003etype of polarization\u003c\/dt\u003e\n\u003cdd\u003eNo impedance\u003c\/dd\u003e\n\u003cdt\u003easynchronous motor control profile\u003c\/dt\u003e\n\u003cdd\u003eVoltage\/frequency ratio;2 points;Voltage\/frequency ratio;automatic IR compensation (U\/f + automatic Uo);Flux vector control without sensor;standard;Voltage\/frequency ratio - Energy Saving;quadratic U\/f;Voltage\/frequency ratio;5 points\u003c\/dd\u003e\n\u003cdt\u003etorque accuracy\u003c\/dt\u003e\n\u003cdd\u003e+\/- 15 %\u003c\/dd\u003e\n\u003cdt\u003etransient overtorque\u003c\/dt\u003e\n\u003cdd\u003e120 % of nominal motor torque +\/- 10 % 60 s\u003c\/dd\u003e\n\u003cdt\u003eacceleration and deceleration ramps\u003c\/dt\u003e\n\u003cdd\u003eAutomatic based on the load;Linear adjustable separately from 0.01 to 3200 s\u003c\/dd\u003e\n\u003cdt\u003emotor slip compensation\u003c\/dt\u003e\n\u003cdd\u003eNot available in voltage\/frequency ratio motor control;Adjustable;Automatic whatever the load\u003c\/dd\u003e\n\u003cdt\u003eswitching frequency\u003c\/dt\u003e\n\u003cdd\u003e6...16 kHz adjustable;12...16 kHz with derating factor\u003c\/dd\u003e\n\u003cdt\u003enominal switching frequency\u003c\/dt\u003e\n\u003cdd\u003e12 kHz\u003c\/dd\u003e\n\u003cdt\u003ebraking to standstill\u003c\/dt\u003e\n\u003cdd\u003eBy DC injection\u003c\/dd\u003e\n\u003cdt\u003eNetwork Frequency\u003c\/dt\u003e\n\u003cdd\u003e47.5...63 Hz\u003c\/dd\u003e\n\u003cdt\u003eprospective line Isc\u003c\/dt\u003e\n\u003cdd\u003e22 kA\u003c\/dd\u003e\n\u003cdt\u003eprotection type\u003c\/dt\u003e\n\u003cdd\u003eOverheating protection drive;Thermal power stage drive;Short-circuit between motor phases drive;Input phase breaks drive;Overcurrent between output phases and earth drive;Overvoltages on the DC bus drive;Break on the control circuit drive;Against exceeding limit speed drive;Line supply overvoltage and undervoltage drive;Line supply undervoltage drive;Against input phase loss drive;Thermal protection motor;Motor phase break motor;With PTC probes motor\u003c\/dd\u003e\n\u003cdt\u003eWidth\u003c\/dt\u003e\n\u003cdd\u003e7.09 in (180 mm)\u003c\/dd\u003e\n\u003cdt\u003eHeight\u003c\/dt\u003e\n\u003cdd\u003e9.13 in (232 mm)\u003c\/dd\u003e\n\u003cdt\u003eDepth\u003c\/dt\u003e\n\u003cdd\u003e6.69 in (170 mm)\u003c\/dd\u003e\n\u003cdt\u003eNet Weight\u003c\/dt\u003e\n\u003cdd\u003e14.22 lb(US) (6.45 kg)\u003c\/dd\u003e\n\u003cdt\u003epollution degree\u003c\/dt\u003e\n\u003cdd\u003e2 IEC 61800-5-1\u003c\/dd\u003e\n\u003cdt\u003eIP degree of protection\u003c\/dt\u003e\n\u003cdd\u003eIP20 on upper part without blanking plate on cover EN\/IEC 61800-5-1;IP20 on upper part without blanking plate on cover EN\/IEC 60529;IP21 EN\/IEC 61800-5-1;IP21 EN\/IEC 60529;IP41 on upper part EN\/IEC 61800-5-1;IP41 on upper part EN\/IEC 60529\u003c\/dd\u003e\n\u003cdt\u003evibration resistance\u003c\/dt\u003e\n\u003cdd\u003e1.5 mm 3…13 Hz)EN\/IEC 60068-2-6;1 gn 13…200 Hz)EN\/IEC 60068-2-8\u003c\/dd\u003e\n\u003cdt\u003eshock resistance\u003c\/dt\u003e\n\u003cdd\u003e15 gn 11 ms IEC 60068-2-27\u003c\/dd\u003e\n\u003cdt\u003eenvironmental characteristic\u003c\/dt\u003e\n\u003cdd\u003eClasses 3C1 IEC 60721-3-3;Classes 3S2 IEC 60721-3-3\u003c\/dd\u003e\n\u003cdt\u003enoise level\u003c\/dt\u003e\n\u003cdd\u003e51 dB 86\/188\/EEC\u003c\/dd\u003e\n\u003cdt\u003eoperating altitude\u003c\/dt\u003e\n\u003cdd\u003e3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m;\u0026lt;= 3280.84 ft (1000 m) without derating\u003c\/dd\u003e\n\u003cdt\u003erelative humidity\u003c\/dt\u003e\n\u003cdd\u003e5…95 % without condensation IEC 60068-2-3;5…95 % without dripping water IEC 60068-2-3\u003c\/dd\u003e\n\u003cdt\u003eambient air temperature for operation\u003c\/dt\u003e\n\u003cdd\u003e14…104 °F (-10…40 °C) without derating);104…122 °F (40…50 °C) with derating factor)\u003c\/dd\u003e\n\u003cdt\u003eoperating position\u003c\/dt\u003e\n\u003cdd\u003eVertical +\/- 10 degree\u003c\/dd\u003e\n\u003cdt\u003eProduct Certifications\u003c\/dt\u003e\n\u003cdd\u003eC-tick;NOM 117;CSA;UL\u003c\/dd\u003e\n\u003cdt\u003eMarking\u003c\/dt\u003e\n\u003cdd\u003eCE\u003c\/dd\u003e\n\u003cdt\u003eStandards\u003c\/dt\u003e\n\u003cdd\u003eEN 61800-3 category C2;EN 61800-3 environments 1 category C2;IEC 61800-3 category C3;EN 61800-3 environments 1 category C3;IEC 61800-3 environments 2 category C3;UL Type 1;IEC 61800-3 environments 1 category C1;IEC 61800-3 environments 1 category C3;EN 61800-3 environments 2 category C3;EN 61800-3 environments 2 category C2;EN 61800-3;IEC 61800-3 category C2;EN 61800-3 environments 1 category C1;EN 61800-5-1;EN 55011 class A group 1;IEC 61800-3 environments 2 category C2;EN 61800-3 category C3;IEC 61800-5-1;EN 61800-3 environments 2 category C1;IEC 61800-3;IEC 61800-3 environments 1 category C2;IEC 61800-3 environments 2 category C1\u003c\/dd\u003e\n\u003cdt\u003eassembly style\u003c\/dt\u003e\n\u003cdd\u003eWith heat sink\u003c\/dd\u003e\n\u003cdt\u003eelectromagnetic compatibility\u003c\/dt\u003e\n\u003cdd\u003eElectrostatic discharge immunity test level 3 IEC 61000-4-2;Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3;Electrical fast transient\/burst immunity test level 4 IEC 61000-4-4;1.2\/50 µs - 8\/20 µs surge immunity test level 3 IEC 61000-4-5;Conducted radio-frequency immunity test level 3 IEC 61000-4-6;Voltage dips and interruptions immunity test IEC 61000-4-11\u003c\/dd\u003e\n\u003cdt\u003eregulation loop\u003c\/dt\u003e\n\u003cdd\u003eAdjustable PI regulator\u003c\/dd\u003e\n\u003cdt\u003eAmbient Air Temperature for Storage\u003c\/dt\u003e\n\u003cdd\u003e-13…158 °F (-25…70 °C)\u003c\/dd\u003e\n\u003cdt\u003eCategory\u003c\/dt\u003e\n\u003cdd\u003e22157-ATV212 1 - 25 HP 460 VOLT\u003c\/dd\u003e\n\u003cdt\u003eDiscount Schedule\u003c\/dt\u003e\n\u003cdd\u003eCP4D\u003c\/dd\u003e\n\u003cdt\u003eGTIN\u003c\/dt\u003e\n\u003cdd\u003e3606480322518\u003c\/dd\u003e\n\u003cdt\u003eReturnability\u003c\/dt\u003e\n\u003cdd\u003eYes\u003c\/dd\u003e\n\u003cdt\u003eCountry of origin\u003c\/dt\u003e\n\u003cdd\u003eID\u003c\/dd\u003e\n\u003cdt\u003eUnit Type of Package 1\u003c\/dt\u003e\n\u003cdd\u003ePCE\u003c\/dd\u003e\n\u003cdt\u003eNumber of Units in Package 1\u003c\/dt\u003e\n\u003cdd\u003e1\u003c\/dd\u003e\n\u003cdt\u003ePackage 1 Height\u003c\/dt\u003e\n\u003cdd\u003e10.63 in (27 cm)\u003c\/dd\u003e\n\u003cdt\u003ePackage 1 Width\u003c\/dt\u003e\n\u003cdd\u003e11.81 in (30 cm)\u003c\/dd\u003e\n\u003cdt\u003ePackage 1 Length\u003c\/dt\u003e\n\u003cdd\u003e9.06 in (23 cm)\u003c\/dd\u003e\n\u003cdt\u003ePackage 1 Weight\u003c\/dt\u003e\n\u003cdd\u003e13.49 lb(US) (6.117 kg)\u003c\/dd\u003e\n\u003cdt\u003eUnit Type of Package 2\u003c\/dt\u003e\n\u003cdd\u003eP06\u003c\/dd\u003e\n\u003cdt\u003eNumber of Units in Package 2\u003c\/dt\u003e\n\u003cdd\u003e10\u003c\/dd\u003e\n\u003cdt\u003ePackage 2 Height\u003c\/dt\u003e\n\u003cdd\u003e29.53 in (75 cm)\u003c\/dd\u003e\n\u003cdt\u003ePackage 2 Width\u003c\/dt\u003e\n\u003cdd\u003e23.62 in (60 cm)\u003c\/dd\u003e\n\u003cdt\u003ePackage 2 Length\u003c\/dt\u003e\n\u003cdd\u003e31.50 in (80 cm)\u003c\/dd\u003e\n\u003cdt\u003ePackage 2 Weight\u003c\/dt\u003e\n\u003cdd\u003e163.52 lb(US) (74.17 kg)\u003c\/dd\u003e\n\u003cdt\u003eWarranty\u003c\/dt\u003e\n\u003cdd\u003e18 months\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003ch3\u003eResources\u003c\/h3\u003e\n\u003cdiv class=\"resources\"\u003e\n\u003ca href=\"https:\/\/www.se.com\/us\/en\/product\/download-pdf\/ATV212HD11N4\" class=\"product__pdf\" target=\"_blank\" rel=\"nofollow noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e  \u003ca href=\"https:\/\/www.se.com\/us\/en\/search\/ATV212HD11N4\" class=\"product__doc\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMore Info\u003c\/a\u003e\n\u003c\/div\u003e  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"Default Title","offer_id":46893295108257,"sku":"ATV212HD11N4","price":28715.25,"currency_code":"BRL","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2216\/8673\/files\/ATV212HD11N4-Altivar-212-VFD-15-hp22_5-amps-400480-VAC-Three-Phase-InputThree-Phase-Output-IP20-Housing-Replaces-the-Altivar21-Square-D.jpg?v=1786979737","url":"https:\/\/www.foxti.com.br\/products\/atv212hd11n4-altivar-212-vfd-15-hp225-amps-400480-vac-three-phase-inputthree-phase-output-ip20-housing-replaces-the-altivar21-square-d","provider":"FoxTI","version":"1.0","type":"link"}